iQ Control Box
10.18.2019
1.800.7.ACCESS • www.stanleyaccess.com • Document # 204143 REV 5 3
Cop
yr
ight 2019, S
tanley Ac
cess T
echnologies, LL
C. All rights r
es
er
ved. R
epr
oduction
in whole or in p
ar
t without the expr
ess wr
itt
en permission o
f S
tanley is pr
ohibit
ed.
2S Operation
ON =
push switch to open, push switch to close;
OFF =
2S mode disabled.
Close Position Tolerance
: Distance from full close that the door transitions from close check to full closed. This parameter
is used when the door can’t get closed and to eliminate recycles caused by obstructions. This sets the position where the
controller interprets the door as fully closed.
Close Obstruction Time
: The amount of time in increments of 0.1 seconds the spring applies force when almost stopped
or stopped when the controller indicates a state of
09
. Before increasing this parameter, check for mechanical issues.
Fire Alarm Mode
:
0 = OFF
:
Keeps the Fire Alarm Mode OFF.
1 = OPEN
:
If not already Fully Open, the controller will ignore sensors and open the door slowly. If the door was
previously obstructed, it will remain at the partially opened position. The controller will cause the door to remain
open/partially opened for the duration of the Fire Alarm activation.
2 = CLOSE
:
Ignore Sensors and Hold Open Switch Mode
: If the door is Fully Closed, the controller will ignore
activation sensors. If not already Fully Closed, the controller will ignore sensors, Hold Open, and close the door.
If the door is obstructed, it will not recycle and leave the motor drive in “freewheel”.
3 = OPEN WITH RETRY
:
If not already Fully Open, the controller will ignore sensors and open the door slowly.
If the door becomes obstructed, it will pause for 0.5 second and reattempt opening. The controller will cause the
door to remain open/attempt opening for the duration of the Fire Alarm Activation.
4 = CLOSE
:
Ignore Hold Open Function Switch Mode
:
If the
door is Fully Closed, the controller will ignore
activation sensors. If not already Fully Closed, the controller will ignore the Hold Open but observe sensors normally
if in automatic or one way. If the door is obstructed, it will not recycle and leave the motor drive in “freewheel”.
Hold Beam Type
: Selects the hold beam type to be used for monitored or non-monitored applications.
Monitored Hold Beams: Photobeam Pro or Optex OS12CT. Refer to wiring diagrams per application.
Hold Open Delay
: Amount of time the door stays open after all sensors have cleared.
I/O Configuration
: Allows Motor 2 Power Close Relay feedback to be used instead of functions normally used with the
selected input:
0 = Default
1 = TB5-7
: Motor 1 Relay Feedback, TB3-9 Motor 2 Relay Feedback. OPEN: If not already Fully Open, the
controller will ignore sensors and open the door slowly. If the door was previously obstructed, it will remain at the
partially opened position. The controller will cause the door to remain open/partially opened for the duration of
the Fire Alarm activation.
2 = TB2-5
: Motor 1 Relay Feedback, TB3-9 = Motor 2 Relay Feedback. If the door is Fully Closed, the controller will
ignore activation sensors. If not already Fully Closed, the controller will ignore sensors, Hold Open, and close the
door. If the door is obstructed, it will not recycle and leave the motor drive in “freewheel”.
Lock Delay
: This allows the lock to mechanically unlock before door motion. Lock Delay only occurs when the door is full
closed (when the control displays
00
). When the door is activated while the door is open, no Lock Delay occurs. Lock Delay
will always occur if a door position switch is active. Value is in 0.1 second increments.
Lock Logic
: Select to choose desired lock logic:
0 = Fail Safe
: U
nlocked when power is removed.
1 = Fail Secure
: Locked when power is removed.
Lock Release Time
: The amount of time (in seconds) that the door will press closed before going open when the lock
needs to release at the closed position. The value of zero disables the lock release.
Lock Release Torque
: The torque used in the lock release state. This parameter sets the maximum current available
to the motor which is directly proportional to the door force.
Magic Touch Engagement
: Determines how smooth the door is to push after a Magic Touch activation.
Magic Touch Hold Open Time
: Delay that the door stays open after all sensors have cleared after a Magic Touch operation.
Parameter is in seconds, with increments of 0.1 seconds.
Magic Touch Sensitivity
: Sets the threshold for manual activation. Setting of 1 is most sensitive. This setting is raised
if false activations are seen.
Manual Mode Sensor Override
: When set to
ON
the door sensors on the approach side will only be activated when a push
plate, Magic Touch, or other Knowing Act activation signal is used.
= NOT SELECTABLE BY KEY PAD/PUSH BUTTONS
Features and Functions