Table 2. iQ Mode Values
Code
iQ Operational Mode
01 Dura-Glide door style—Single Motor
02 Dura-Glide door style—Dual Motor
03 Magic-Swing Door Style—Single Motor
04 Magic-Swing Door Style—Dual Motor
05 Magic-Force Door Style—Single Motor
06 Magic-Force Door Style—Dual Motor
07 Magic-Force Door Style—Single Motor Low Energy
08 Magic-Force Door Style—Dual Motor Low Energy
09 Fold door style--Single Motor
10 Fold door Style--Dual Motor
Description
Index
iQ Mode Specific Door Operational Values - These depend upon the mode selected
00-89
Reserved
90-95
Command: Restart FIS. Entering
01
will cause FIS to restart.
96
Firmware: Entering
01
will display
FE
followed by two pairs of digits followed by
FE
.
For example, if the firmware is 0609, the controller will display
FE
06 09 FE
.
97
Command: Restart auto configuration. Entering
01
sets the Control Box to
A1,
which keeps all
previous values and then the Control Box re-learns the encoder count.
98
Command: Lock. Entering
01
will lock all VALUE imports except this INDEX. This prevents
inadvertent changes to input values. VALUES may be unlocked by entering
00
in this INDEX.
99
Table 3. Index List