iQ Control Box
18 Document # 204143 REV 5 • www.stanleyaccess.com • 1.800.7.ACCESS
Cop
yr
ight 2019, S
tanley Ac
cess T
echnologies, LL
C. All rights r
es
er
ved. R
epr
oduction
in whole or in p
ar
t without the expr
ess wr
itt
en permission o
f S
tanley is pr
ohibit
ed.
10.18.2019
Door State
Description
00
Door State is Closed.
02
Door State is Opening.
04
Door State is in Open Check.
06
Door State is Full Open.
09
Door State is in Close Check.
15
Door State is Open Stop.
16
Door State is Close Stop.
18
Door State is in Power Close.
19
Door State is in Lock Release.
21
Door State is in Power Assist.
22
Door State is in Power Close at Closed.
NOTES
:
• If the current status code is “Normal operation—All OK”, the iQ will show the current door state.
Otherwise, the iQ alternates between showing the current status code and the door state.
•
d1
and
d2
displayed when controlling more than one door.
Any state that follows
d1
is referencing door #1.
• Any state that follows
d2
is referencing door #2
Table 6. Door States
Door States
Table 5. Status Codes (continued)
Status Code
Description
Remedy/Cause
E2 / ho
Door Held Open
Use best practices to troubleshoot using
hand held device and provided
wiring diagrams.
E3
Door Length Error
1. Check mechanical issues, components.
2. Re-do First Installation Sequence (FIS).
E5
Motor Drive Error
E6
Power Close Control Failure
Verify Power Close Speed Module wiring.
F0
Stall Sensor Failure
Verify sensor wiring and safety logic setting.
F1
Approach Sensor Failure
Verify sensor wiring and safety logic setting.
F2
Hold Beam Sensor Failure
Verify sensor wiring and safety logic setting.
F4
Safety 1 Sensor Failure
Verify sensor wiring and safety logic setting.
F5
Safety 2 Sensor Failure
Verify sensor wiring and safety logic setting.
FA
Fire Alarm Active