iQ Control Box
4 Document # 204143 REV 5 • www.stanleyaccess.com • 1.800.7.ACCESS
Cop
yr
ight 2019, S
tanley Ac
cess T
echnologies, LL
C. All rights r
es
er
ved. R
epr
oduction
in whole or in p
ar
t without the expr
ess wr
itt
en permission o
f S
tanley is pr
ohibit
ed.
10.18.2019
Motor Starting Speed
: Affects the smoothness of the transition to powered door motion after manual door use.
No Reverse on Obstruction
: Door will not recycle on close obstruction. Used in Low Energy only.
Off Mode
: If set to close, all sensors are ignored when function switch is off.
Open Acceleration
: Affects how responsive the door is to speed changes in the opening direction. This parameter is used
when the door is lagging open speed. Startup torque and startup length should be investigated prior to increasing. This
parameter affects all open motion speeds: open speed, open check speed, open learn speed, as well as open braking.
Open Braking
: Adjusts how quickly the door slows down prior to check speed. Increasing this parameter increases
braking power.
Open Check Length
: The percent of door travel in which the door starts to slow down to open check speed. This parameter
typically is adjusted based on door weight and open speed setting.
Open Check Obstruction Time
: The amount of time in increments of 0.1 seconds that the door applies force when almost
stopped or stopped when the controller indicates a state of
04
. Before increasing this parameter, check for mechanical
issues, as well as speed and torque parameter settings.
Open Check Recycle Speed
: The percent of Open Speed that is used when recycling in the Open Check Length.
Open Check Speed
: The speed used during normal operation in the open check state
04
prior to arriving at full open.
This speed is set to determine how fast the door arrives at full open after open speed. This parameter sets the target speed
setting. Other parameters like open check torque, open acceleration, and open braking, as well as door properties like
friction, door length, and door weight affect door speed.
Open Check Torque
: The torque used during normal operation in open check state. This torque must be set to comply with
ANSI/BHMA door force requirements. This parameter sets the maximum current available to the motor which is directly
proportional to the door force. This torque setting is used in conjunction with Open Check Speed.
Open Learn Speed
: The speed used on power up, during FIS, after an obstruction, and return from breakout. The controller
display may indicate either 02 or 04 as a door state and still use Open Learn Speed based on the conditions listed prior. This
speed is typically set higher than check speed, to allow faster door motion when not in the check zones, but still slower door
motion than normal operation. This parameter sets the target speed setting. Other parameters like open learn torque, and
open acceleration as well as door properties like friction, door length, and door weight affect door speed.
Open Learn Torque
: The torque used on power up, during FIS, after an obstruction, and return from breakout. This torque
must be set to comply with ANSI/BHMA door force requirements. This parameter sets the maximum current available to the
motor which is directly proportional to the door force. This torque setting is used in conjunction with open learn speed.
Open Obstruction Time
: The amount of time in increments of 0.1 seconds the door applies force when almost stopped or
stopped when the controller indicates a state of “02”. Before increasing this parameter, check for mechanical issues, as well
as speed and torque parameter settings.
Open Speed
: The speed used during normal operation in the opening state
02
. This parameter sets the target speed setting.
Other parameters like open torque, open startup torque, open startup length, and open acceleration, as well as door
properties like friction, door length, and door weight affect door speed.
Open Startup Length
: The percent of door length in which the Open Startup Torque parameter is used. These parameters
are used to overcome friction encountered at the beginning of open door motion. This parameter should be set as low as
possible to ensure reliable operation.
Open Startup Torque
: Open Startup Torque used when entering the opening state
02
and recycles. It is used for a
configurable door length (determined by the Open Startup Length parameter). After this door length, the torque setting
will revert to the Open Torque. This torque should be set greater than Open Torque to ensure that the controller can start
door motion, overcome static friction, and avoid obstructions. This torque must be set to comply with ANSI/BHMA door
force requirements. This parameter sets the maximum current available to the motor which is directly proportional to
the door force.
Open Stop
: The distance from full open that the door will stop in 0.1 degree increments. This parameter is used to minimize
excessive oscillations that are seen at full open.
Open Torque
: The torque used during normal operation following the end of Open Startup Length. This torque must be set to
comply with ANSI/BHMA door force requirements. This parameter sets the maximum current available to the motor which is
directly proportional to the door force. This torque setting is used in conjunction with Open Speed.
Operate Delay
: Delays the motion of the door after the operate signal is received. Value is in 0.1 second increments.
Overspeed Braking Angle
: Determines the position the door transitions to Open Check during manual operation following
a Knowing Act. Setting the value to 99 disables the transition to Open Check.
Overspeed Resistance
: Sets the sensitivity to external factors that allow the door to be used manually. Increasing this
parameter will desensitize door motion to factors such as wind, stack pressure, and manual use.
Features and Functions (continued)