F
4
8
3
0
5
0
3
T
h
e
c
o
p
y
in
g
,
d
is
tr
ib
u
ti
o
n
a
n
d
u
ti
li
z
a
ti
o
n
o
f
th
is
d
o
c
u
m
e
n
t
a
s
w
e
ll
a
s
t
h
e
c
o
m
m
u
n
ic
a
ti
o
n
o
f
is
t
c
o
n
te
n
ts
t
o
o
th
e
rs
w
it
h
o
u
t
e
x
p
re
s
s
e
d
a
u
th
o
ri
z
a
ti
o
n
i
s
p
ro
h
ib
it
e
d
.
O
ff
e
n
d
e
rs
w
il
l
b
e
h
e
ld
l
ia
b
le
f
o
r
th
e
p
a
y
m
e
n
t
o
f
d
a
m
a
g
e
s
.
A
ll
ri
g
h
ts
r
e
s
e
rv
e
d
i
n
t
h
e
e
v
e
n
t
o
f
th
e
g
ra
n
t
o
f
a
p
a
te
n
t,
u
ti
lit
y
m
o
d
e
l
o
r
o
rn
a
m
e
n
ta
l
d
e
s
ig
n
r
e
g
is
tr
a
ti
o
n
.
W
e
it
e
rg
a
b
e
s
o
w
ie
V
e
rv
ie
lf
ä
lt
ig
u
n
g
d
ie
s
e
s
D
o
k
u
m
e
n
ts
,
V
e
rw
e
rt
u
n
g
u
n
d
M
it
te
ilu
n
g
s
e
in
e
s
I
n
h
a
lt
s
s
in
d
v
e
rb
o
te
n
,
s
o
w
e
it
n
ic
h
t
a
u
s
d
rü
c
k
lic
h
g
e
s
ta
tt
e
t.
Z
u
w
id
e
r-
h
a
n
d
lu
n
g
e
n
v
e
rp
fli
c
h
te
n
z
u
S
c
h
a
d
e
n
e
rs
a
tz
.
A
lle
R
e
c
h
te
f
ü
r
d
e
n
F
a
ll
d
e
r
P
a
te
n
t-
,
G
e
b
ra
u
c
h
s
m
u
s
te
r-
o
d
e
r
G
e
s
c
h
m
a
c
k
s
m
u
s
te
re
in
tr
a
g
v
o
rb
e
h
a
lt
e
n
.
Certification drawing
April Toby
2004
94 006 01 31 2
none
CSA
Faulring
A
10 / 2004
T. Stahl
B
17.08.09
Einsiedler
Class I, Zone 1, Group IIC/IIB or
Class I, Div. 2, Groups A, B, C, D
Hazardous (Classified) Locations
Notes:
1.) Suitable separation must be maintained between Non I.S.
wiring of the relay circuits and I.S. wiring of the I/O modules
and the I.S. bus of the IS1 system.
2.) Do not disconnect Non I.S. field wiring to X1 or DOM Relay
base (9490/11-3.) from the BusRail unless area is known to
be non-hazardous.
3.) In hazardous locations classified Class I, Zone 1, Non I.S.
field wiring to the Ex e terminals X1 must meet the Class I,
Zone 1 wiring requirements of Canadian Electrical Code,
Part 1.
4.) At type 9477/12-06-12 relay circuit are grouped to two
groups, each using a common source. Additional protection
may be required to guarantee IP30 protection if a group is
only partly wired.
The Digital Output Relay Type 9477/12-0.-12 is an explosion protected
electrical apparatus for installation in a Class I, Zone 1, Group IIC/IIB or
Class I, Div. 2, Groups A, B, C, D hazardous location in accordance with
the Canadian Electrical Code, Part I that uses relay contacts to control up
to eight Non-I.S. circuits.
The internal system circuits are safely galvanically isolated from all output
circuits up to a peak voltage of 375 V.
Type 9477/12-08-12
Relay circuits may not exceed the following nominal values:
U
n
60 V AC
30 V DC
I
n
2 A
2 A
P
n
100 VA
-
The output circuits are safely galvanically isolated from earth and from
each other up to an operating voltage of 60 V.
Connection allocation (X1)
Output
Terminal
0
1
2
3
4
5
6
7
1, 2
3, 4
5, 6
7, 8
9, 10
11, 12
13, 14
15, 16
Type 9477/12-06-12
Relay circuits may not exceed the following nominal values:
The output circuits are safely galvanically isolated from earth and from
each other up to an operating voltage of 250 V.
Connection allocation (X1)
U
n
250 V AC
30 V DC
110 V DC
220 V DC
I
n
2 A
2 A
0,3 A
0,12 A
P
n
100 VA
-
-
-
Source
Output
Terminal
0
1
0
1
2
3
5
7
1
9
3
4
5
11
13
15
13 of 14
Non I.S. terminals X1
Non I.S. terminals X1
Digital Output Module Relay
Type 9477/12-0.12
Содержание IS1
Страница 13: ......