193
Winterize
7
9
11
8
10
12
Open the boiler drain valve (Caution Hot Water)
Use a shop vac to remove remaining water in the
boiler.
If machine is equipped with hydraulic oil cooler
perform steps 11-12.
Remove the bottom feed pump plug with a 7/16”
wrench.
After the boiler is drained, disconnect the boiler drain
camlock and remove the assembly.
Remove the supply water filter and housing.
Remove the return hose on the front left water tank
and blow compressed air through the hose. This will
clear water out of the hydraulic oil cooler. Water from
the cooler should drain out of the bottom of the feed
water pump where the plug was removed.