Faults
Fault 1210: Boiler Controller Output Supply 3 Voltage High
Check tractor battery. If problem persists: contact dealer / replace controller.
Fault 1211: Boiler Controller Output Supply 3 Amperage High
Check tractor battery. If problem persists: contact dealer / replace controller.
Fault 1212: Boiler Controller Output Supply 4 Voltage Low
Check tractor battery. If problem persists: contact dealer / replace controller.
Causes
Troubleshooting
Fixes
• Blown fuse #6 (main fuse
block).
• Faulty hydraulic fan ON/OFF
solenoid causing blown fuse #6.
• Faulty feed pump ON/OFF
solenoid causing blown fuse #6.
• Check fuse for blown
symptoms.
• Inspect hydraulic fan ON/OFF
solenoid wiring and connection.
• Inspect feed pump ON/OFF
solenoid wiring and connection.
• Replace fuse #6 (7.5 amp).
• Replace hydraulic fan ON/OFF
solenoid.
• Replace feed pump ON/OFF
solenoid.
Fault 1213: Boiler Controller Output Supply 4 Voltage High
Check tractor battery. If problem persists: contact dealer / replace controller.
Fault 1214: Boiler Controller Output Supply 4 Amperage High
Check tractor battery. If problem persists: contact dealer / replace controller.
Fault 1215: Boiler Controller 12 V “Sensor” Supply Too Low
Triggers when voltage is under 10.8 V
Check tractor battery. If problem persists: contact dealer / replace controller.
Fault 1216: Boiler Controller 12 V “Sensor” Supply Too High
Triggers when voltage is over 13.2 V
Check tractor battery. If problem persists: contact dealer / replace controller.
Fault 1217: Boiler Controller 8.5 V Supply Too Low
Triggers when voltage is under 8.15 V
Check tractor battery. If problem persists: contact dealer / replace controller.
Fault 1218: Boiler Controller 8.5 V Supply Too High
Triggers when voltage is over 8.85 V
Check tractor battery. If problem persists: contact dealer / replace controller.