STACK Dash-2 Kart Logger
6. Troubleshooting
Users Guide
41
Symptom
Possible Cause
Remedy
Notes
Displayed RPM value
too high or too low by a
constant %-age
amount.
System configured
with wrong number
of engine cylinders.
Reconfigure system to
correct number of
cylinders.
Ignition systems
may either:
-produce
"waste" sparks
giving double
the number of
cylinders per
revolution
Ignition system
pulses per
revolution not
same as number of
cylinders
Reconfigure system to
correct number of pulses
per revolution.
Display and alarm light
flash when the engine
is running
Intermittent alarm
caused by a
parameter with its
alarm level set too
close to the normal
operating value
Either change the value for
the alarm or turn the alarm
off
Press Switch 2
to see which
sensor is
causing the
alarm.