7. Troubleshooting
STACK Dash-2 Kart Logger
38
Users Guide
7. Troubleshooting
7. Troubleshooting
Symptom
Possible Cause
Remedy
Notes
Display is dead
Power switch is off
Turn on
Battery is dead
Recharge or replace
battery
Power connection
is faulty
Check if battery is
connected correctly. Check
power lead continuity
!! LOW BATT !!
warning on display
Battery is almost
dead
Recharge or replace
battery
Power connection
is faulty
Check power lead
continuity
Display flashes and dial
pointer resets or
vibrates
Battery is almost
dead
Recharge or replace
battery
Power connection
is faulty
Check power lead
continuity
Display gives a fixed
temperature reading
Temperature
sensor has failed
Replace sensor
Disconnect
sensor.
Faulty sensor
connections
Check continuity of sensor
leads
Check harness
for short circuit
Display gives a fixed
reading of 0
°
C or 0
°
F
when temperature is
above 70
°
C or 160
°
F
A temperature
sensor has failed
Replace sensor
Faulty sensor
connections
Check continuity of sensor
leads for open circuits.
All sensors show fixed
high values
Switch 1 (Peaks)
faulty
Return unit for repair
Peak values not updated Gate value set too
high
Change Gate RPM in the
display configuration menu
Internal memory
battery dead
Return unit to Stack for new
battery service
Display shows
!!MEM BATT!!
warning on power
up