SECTION TWO – Heater Installation
PPPPrrrreeeessssssssuuuurrrreeee SSSSwwwwiiiittttcccchhhh SSSSeeeettttttttiiiinnnnggggssss::::
The water Pressure Switch turns off the burner if the
water flow is interrupted. If the water flow is restricted,
the water Pressure Switch may prevent the burner from
firing and cause the “Service System” light to come on.
For deck-level heater installations, the Pressure Switch
is factory-set at 3 psi.
If the Pressure Switch is 2 to 4 feet
below
the pool water
level, turn the star-wheel on the switch clockwise
(
)
to raise the pressure setting. See Figure 2-17, below.
If the Pressure Switch is 2 to 5 feet
above
the pool water
level, turn the star-wheel on the switch
counter
-clockwise
(
)
to lower the pressure setting.
See Figure 2-17, below.
NNNNOOOOTTTTEEEE:::: When the Pressure Switch is more than 4feet
below the pool water level, or more than 5feet above the
pool water level, a Flow Switch is required. The Pressure
Switch is no longer adequate for the installation.
W
W
W
Waaaatttteeeerrrr PPPPiiiippppiiiinnnngggg SSSSppppeeeecccciiiiffffiiiiccccaaaattttiiiioooonnnnssss
The heater is designed to be connected directly to
2-inch PVC pipe, using the integral unions provided.
The low thermal mass of the heater prevents overheat-
ing of the piping if the pump stops. There is no need
for a heat sink.
Improper operation of chemical feeders
can cause severe damage to the heater
, which is not
covered by the warranty. Install the chemical feeder
downstream of the heater. Equip the chemical feeder
with an anti-syphon device to prevent chemicals from
siphoning into the heater if the pump stops.
W
W
W
Waaaatttteeeerrrr FFFFlllloooowwww RRRRaaaatttteeee RRRReeeeqqqquuuuiiiirrrreeeemmmmeeeennnnttttssss
Maximum and minimum water flow rates required by
the heater are listed below:
2-17
Heater Water Connections
2734 1296
Lower Pressure
Raise Pressure
Turn star wheel to
raise pressure set
point if pressure
switch is more than
2 feet (.6 M)
below
water level
Turn star wheel
to
lower pressure
set point if pressure
switch is more than
5 feet (1.5 M)
above
water level
Back of pressure switch
has a reference scale.
Figure 2-17: Pressure Switch Adjustment
Table 2-M: Maximum/Minimum Flow Rate
Maximum and Minimum
Flow Rate in GPM (LPM)
Model
Minimum Flow
Maximum Flow
200
20 (76 LPM)
120 (454 LPM)
333
33 (114 LPM)
120 (454 LPM)
400
40 (151 LPM)
120 (454 LPM)