© SprayTECH Corporation. All rights reserved.
5
Solution
1. Adjust the air flow adjustment knob
2. Clean or replace the filters
1. Clean or replace the filters
1. Check the power supply
2. Check and replace the fuse
3. Have the brushes replaced at an authorized
CAPSpray service center
1. Have the brushes replaced at an authorized
CAPSpray service center
2. Replace the turbine (contact a CAPSpray
service technician)
Cause
1. Air flow adjustment knob on the spray
gun is turned off
2. Air filters are clogged
1. Air filters are clogged
1. No power at the power supply
2. The fuse is blown
3. Worn turbine brushes
1. Worn turbine brushes
2. Damaged commutator
English
Troubleshooting
Problem
Restricted air flow or no air
flow
Filter warning light is on
The turbine has no power
Excessive arcing/sparking in
the turbine
Patents
These products may be covered under one or more of the following U.S. patents:
5,702,131
5,655,714
5,639,222
5,573,371
5,558,492
5,556,255
5,550,336
5,423,395
5,284,301
5,183,207
5,174,610
D365,569
5,078,323
5,078,322
5,074,467
5,050,804
B1 5,772,711
D331,095
D321,926
Содержание CAPspray CS8100
Страница 17: ......