Inspecting and Testing
Model: T621
Inspection point: Motor voltage test at the drive board
Inspection method: 1. Select the VDC setting on the multi-meter. Place probes on M+M- connectors on the drive
board.
2.
Press the SPEED<▲> key. The motor should operate, allowing you to measure motor
voltage.
Speed
Drive board voltage
Motor specifications
Highest speed
100-120 VDC
110V
Lowest speed
210-230 VDC
220V
4-4-1
Place probes on M+M- connectors