Other Instructions
Model: T621
Malfunction: SERVICE NEEDED-APPLY LUBE
Circumstance: The message
“SERVICE NEEDED-APPLY LUBE” appears, and the unit stops operating.
At 4000 km of use, the lubrication service prompt
“SERVICE NEEDED-APPLY LUBE” appears.
Troubleshooting: 1. Insert the lube applicator tube as shown.
2. Simultaneously press and hold <0
>+INCLINE<▲>+INCLINE<▼> for two seconds to
activate the lubrication mode. The display counts down (3, 2, 1). The speed window shows 2.0 KPH
(or 1.3 MPH), and the walk belt starts rotating.
3. Squeeze the bottle of lubricant into the applicator tube. Let the unit operate slowly for ten minutes.
Allow the lubricant to disperse onto the walk belt.
4. After ten minutes, press the <STOP> key and remove the lube applicator tube.
The display program will clear the lube distance memory. A new lubrication distance will begin to accrue.
5. After lubricating the walk belt, operate the treadmill for ten minutes to let the lubricant disperse.
3-12-1