Troubleshooting
Model: T621
Malfunction: No start up. Unit does not operate.
Circumstance of malfunction: Turn unit power on; the power indicator LED does not light.
Possible causes: 1. Transformer problem.
2. Cables are not connected properly, or the drive board is malfunctioning.
Troubleshooting: 1. Inspect all cable connections.
2. Inspect whether LED2 on the drive board lights.
A. If LED2 does not light, inspect the transformer fuse
and measure transformer input and output voltage.
3. Inspect whether LED1 on the display board lights.
A. If it does not light, inspect cable connections from the display
to the drive board.
B. If it does light, inspect the display IC. Re-install the display IC.
3-2-2
Drive
board
Display
board
Transformer
FUSE
AC1
AC2
LED
LED
Filter
Power led
Transformer voltage
Transformer
voltage(AC)
(red-red)
(blue-blue)
110V (red)
220V(blue)
black-black
12.5V
white-white
12.5V
orange-orange
29V
yellow-yellow
11.5V
Transformer fuse
Program IC
LED2 power indicator
Lit indicates unit is sending 5 VDC
power supply to the display.
Содержание T621
Страница 1: ...T621 Repair Manual Electronics ...
Страница 4: ...1 1 Product Picture T621 1 1 1 ...
Страница 5: ...1 2 Display T621 1 2 1 ...
Страница 6: ...1 3 Component Placement T621 Display 1 3 1 Telemetry heart rate receiver board Display board ...
Страница 7: ...1 3 Component Placement T621 Display 1 3 2 HTR board Bridge board Soft keys Safety key board ...
Страница 11: ...1 5 Connections T621 Bridge Board 1 5 2 To safety key board To HTR board To display ...
Страница 13: ...1 6 Indicator LEDs T621 Display Board 1 6 1 HR indicator Power indicator Lit indicates display has power ...