Troubleshooting
Model: T621
Malfunction: The fuse has broken.
Circumstance: 1. Press the speed up key. The motor rotates. Then the fuse blows.
Possible cause: 1. Motor windings have an electrical short.
2. Drive board malfunction.
Troubleshooting: 1. Replace the drive board as a test.
2. Replace the motor as a test.
3. Replace the speed sensor as a test.
3-6-2
Drive board
Display board
Sensor
Motor
Drive board
Motor
Sensor
Содержание T621
Страница 1: ...T621 Repair Manual Electronics ...
Страница 4: ...1 1 Product Picture T621 1 1 1 ...
Страница 5: ...1 2 Display T621 1 2 1 ...
Страница 6: ...1 3 Component Placement T621 Display 1 3 1 Telemetry heart rate receiver board Display board ...
Страница 7: ...1 3 Component Placement T621 Display 1 3 2 HTR board Bridge board Soft keys Safety key board ...
Страница 11: ...1 5 Connections T621 Bridge Board 1 5 2 To safety key board To HTR board To display ...
Страница 13: ...1 6 Indicator LEDs T621 Display Board 1 6 1 HR indicator Power indicator Lit indicates display has power ...