5
1. PRE-ORDER CHECKLIST (CONTINUED)
Legend:
I= Inverter
B= Boost Converter
C= Cardio Unit
Y= Y-Connector
Parallel:
Tree:
C
Y
I
B
C
B
C
B
C
B
C
B
B
C
C
Y
I
B
C
B
C
B
B
C
C
B
Y
C
B
B
C
1. Select the number and type of Cardio Units desired.
2. Determine the number of Pods desired: 1 Inverter is required per Pod. Up to 10 Cardio Units can
be connected in a single Pod.
Series:
I
B
C
B
C
B
C
3. Construct a site plan by laying out desired equipment locations and assigned footprints on a scale
drawing. Include all Inverters, Cardio Units, and Boost Converter, plus Y-Connectors if needed. There
is a space planner application on our website that can be used to do this at: http://www.sportsartamerica.
com/SAF/space_planner.asp or you can ask your SportsArt Rep to provide site planning assistance.
4. Determine the Boost Converter cable lengths required. See page 4 for available lengths. Add up
all Boost Converter cable lengths plus 12” for each Boost Converter in the Pod and compare the
total with the maximum allowed length of 34m (111’ 7”).
5. Determine the number of raceways needed to cover exposed Boost Converter cables. Each
raceway is 1m or 39” long.*
*Note: Included in the standard order are four raceways for the Inverter and one for each Cardio Unit.
It is recommended that all of the exposed cables should be covered with the raceways to minimize trip
hazards.
Additional raceways and one custom length cable will be provided at no extra charge if specified at the
time of original order. All Y-Connectors, cables and raceways ordered after the original order will be
charged.
Cardio Units can be arranged in many topologies within a pod. These are some of the configurations possible:
Pre-Order Checklist
Pre-Order Checklist