13
3. INSTALLATION PROCEDURES OVERVIEW (CONTINUED)
CAUTION
These servicing instructions are for use by qualified personnel only. To reduce the risk of electric
shock, do not perform any servicing other than that specified in the operating instructions unless you
are qualified to do so.
Both AC and DC voltage sources are terminated inside this equipment. Each circuit must be individually discon-
nected before servicing. Do not remove cover until 5 minutes after disconnecting all sources of supply.
This unit contains active anti-islanding protection.
Operation temperature range: +5~+35 C
Storage temperature range: +5~+35 C
Enclosure Type 1: “indoor use only”
Inverter Electronic Specifications
DC
Maximum input voltage 480V DC
Operating voltage range 290~470V DC
Maximum input current 6A
Maximum utility backfeed current 2A
AC
Nominal operating voltage 200~240V AC
Nominal operating frequency 50Hz/60Hz(by jumper setting)
Grid power voltage range 183~264V AC
Operating frequency range
47.5~50.2Hz(for 50Hz)
59.3~60.5Hz(for 60Hz)
Maximum continuous output power 2000W
Maximum continuous output current 10A
Maximum output over current protection 15A
Output power factor 0.99
Procedure 2: Hardwire Inverter to a Dedicated Circuit Breaker
Installation Procedures Overview
Installation Procedures Overview