RECOMMEND
A
TIONS OF USE
- Y
ou can restart a program’
s cycle on another muscle zone
or change the program while remaining on the same muscle zone,
with
out e
xceeding however 40 min use per muscle zone and per day
.
- For optimum use, refer to the diagrams shown in this leaflet.
- Clean the unit and its cables with a cloth dampened with a disinfecting solution (mercr
yl type) diluted in water at 1/10th.
TIPS
EXPLANA
TIONS FOR SMALL SIZES :
If the belt overlaps with electrodes on the body
, fold the overlapping part of the belt by means of scratch sections
.
SAFETY CHECK
Ever
y 24 months, check the following points :
1 - Check for superficial degradation of the equipment
2 -
Check proper operation of the unit :
* legible display
* switch, contact
3 -
Measure electric values :
* with a 500-ohm load, the current must not exceed
100 V
.
4 -
Check reliability of accessories :
* adhesive electrodes in good condition (no tears, no
material defects)
* wire of adhesive electrodes in good condition.
CLEANING AND MAINTENANCE CONDITIONS FOR
THE BEL
T AND SHORTS
.
- CAUTION :
Machine washing and soaking is PROHIBITED
.
- Do not dr
y-clean
- Do not use bleach
- Clean accessories with a humid sponge soaked with detergent and wipe with a cloth
.
- Clean the unit with a cloth soaked in with disinfectant
(Mercr
yl type) diluted with water
at 1/10th.
- Clean the electrodes with a mix of water/hypoallergenic detergent, then rinse thoroughly
.
P
C1
VI. Recommendation of use
W
ARNINGS :
Do not use the device by driving or by working on a machine.
Do not use this electro stimulation unit in a damp environment, a bathroom, a sauna, or close to electric machiner
y connected t
o mains and earthed,
or even piping earthed.
The simultaneous connection of a patient to a high frequency surgical unit
may cause
burns
at
the points of contact of the stim
ulator’
s electrodes, and
the stim
ulator may be damaged. Operation in close proximity of a short wave ther
apy unit may cause instability in the stimulator’
s output power
.
PRECA
UTIONS OF USE
* Keep the belt and the shorts away from heat
* Do not leave within reach of children
* Ask your doctor’
s advice :
- if you have electronic or metallic implants (pins, etc.)
- in case of skin condition (wounds,…)
The unit is recommended for physiotherapists for functional re-education.
RECOMMEND
A
TIONS :
Please apply regulations enforced in your countr
y
when disposing your product at its end of life.
Therefore, please discard it in a location planned to this effect,
ensuring it is disposed in an environment-friendly manner
•
Use only on those parts of the body for which the accessories were designed
.
•
Functions only on batteries
•
Not to connect to another source of power
Type of current
Number of programmes
Number of phases variations
Number of adjustable independent outputs
Current
Frequency range
Pulse width range
Power
Unit dimensions and weight
Automatic stop at end of each program
Activation safety
Detection absence of electrodes or of contact
Indicator of power
Indicator of weak and/or defective batterie
Indicator absence contact
belt / shor
ts
Indicator of the programs
Temperature of storage
Relative humidity of storage
Temperature of use
Relative humidity of use
Connection device
belt / shor
ts
Caution : Read the manuel thoroughly
RoHS : The unit are free of materials likely to have a
negative impact on the environment
Guarantee
VII. T
ECHNICAL
SPECIFICA
TIONS
ST
AND
ARDS
• Unit : EN60601-1 EN60601-2-10
• Belt / shor
ts: ISO 10993
•
Electro-conducting massage cream
150 ml / 5,1 Fl Oz : 76/768/CEE
• Classification type BF
BEL
T AND SHORTS
:
• Size (unisex) : from 34 to 60
• Length of the unfolded belt : 126 cm
• Fabric : polyester
• Built-in electrodes : carbonated silicon.
(Directive 89/336/CEE)
UNIT :
Dual phase
4 programs
79
2
From 0 to 70 mA - From 0 to 1000
Ω
1 to 100 Hz
160 to 320 µs
3 x 1,5 V batteries type LR6 (not provided)
69 x 43 x 87 (h) mm - 106 g
Yes - about 4 min 30 sec
100%
yes detection independent on each of the 2 outputs
bar graph - LCD display
yes - LCD display
yes - LCD display
pictograms - LCD display
0°C to + 45°C
10% to 90%
+ 5°C to + 45°C
20% to 65%
wires - plugs ø 2 mm male
2 years
R
oHS
(2002/95/EC)
GU
ARANTEE :
The belt, the shorts and the cream are designed for personal
use. For reasons of hygiene, there will be neither trade
-in nor
exc
hange.
The belt life is limited to 10 months.