89
Spohn & Burkhardt
DRAFT
Variant with spacer 53035 and 53207
Figure 43.
18
18
17
17
4
4
15
15
15
15
Disconnecting electrical connections: Variant with spacer 53035 and 53207
1. Disconnect the system from the supply of electrical power.
1. Open the consoles,
see
chapter 4.2. “Electrical connection”
point 9.
2. Disconnect the electrical connections.
3. Undo the lock nut (
21
) on the cable opening (
17
) and remove the corrugated tube (
22
),
4. Pull the cables out of the corrugated tube (
22
).
5. Undo the two securing screws (
18
) on the spacer (
4
).
6. Tip the control stand in the direction of the hinges (
15
), make sure that the control stand is secured
against tipping back and is placed on a suitable surface.
7. Disconnect the corresponding cables from the terminal block (
20
(see Figure 16 “Cable entry”, page
66).
8. Tip back the control stand and tighten the two locking screws (
18
) in the spacer (
4
).
Variant with spacer 52832; 43666 and 53153
Figure 44.
17
17
4
19
23
Electrical connection: Variant with spacer 52832; 43666 and 53153
1. Disconnect the system from the supply of electrical power.
2. Open the consoles,
see
chapter 4.2. “Electrical connection”
point 9.
3. Disconnect the electrical connections.
Содержание FS Series
Страница 46: ...DRAFT 46 Spohn Burkhardt 13 Konformitätserklärung ...
Страница 47: ...47 Spohn Burkhardt DRAFT ...
Страница 91: ...91 Spohn Burkhardt DRAFT 13 Declaration of conformity ...
Страница 96: ...DRAFT 4 Spohn Burkhardt 8 2 Heizungs und Lüftungssteuerung demontieren 19 9 Ersatzteile 20 10 Entsorgung 20 ...
Страница 129: ...37 Spohn Burkhardt ...
Страница 130: ...38 Spohn Burkhardt ...
Страница 131: ...39 Spohn Burkhardt ...
Страница 132: ...Spohn Burkhardt GmbH Co KG Mauergasse 5 89143 Blaubeuren Germany Tel 49 7344 171 0 Web www spobu de Mail info spobu de ...