31
Spohn & Burkhardt
DRAFT
Rotary switch/but-
ton
Function
"Temperature" rotary switch
Turn the "Temperature" rotary switch (
12
) to the left or right to set the required
temperature.
"Fan" rotary switch
Turn the "Fan" rotary switch (
14
) to the left or right to set the required fan speed.
"Off" – the fan is switched off.
"Auto" – the fan speed is controlled automatically.
"Hi" – highest fan speed.
The fan speed can be adjusted in steps between "Auto" and "Hi".
"Defrost" button
Press the "Defrost" button (
13
),
The heater and the maximum fan speed are set to remove ice or condensation.
Press the "Defrost" button (
13
) again to switch off the "Defrost" function.
"Error" warning light
The "Error" warning light (
15
) illuminates if an error occurs.
6. Servicing
Danger!
All tasks on the device are only allowed to be undertaken by specialist personnel taking
into account the relevant safety regulations. Always pay attention to the safety instruc-
tions in
Servicing measure
Interval
Function test
before starting work
Visual inspection/cleaning
regularly
Check screw joints
regularly
Function test
regularly
Replace filters
every 250 to 500 hours of operation(depending on
the degree of soiling)
Replace ventilation grilles
if it is heavily soiled or defective
Replace air outlet nozzles
if it is heavily soiled or defective
Inspection
every 6 months
Содержание FS Series
Страница 46: ...DRAFT 46 Spohn Burkhardt 13 Konformitätserklärung ...
Страница 47: ...47 Spohn Burkhardt DRAFT ...
Страница 91: ...91 Spohn Burkhardt DRAFT 13 Declaration of conformity ...
Страница 96: ...DRAFT 4 Spohn Burkhardt 8 2 Heizungs und Lüftungssteuerung demontieren 19 9 Ersatzteile 20 10 Entsorgung 20 ...
Страница 129: ...37 Spohn Burkhardt ...
Страница 130: ...38 Spohn Burkhardt ...
Страница 131: ...39 Spohn Burkhardt ...
Страница 132: ...Spohn Burkhardt GmbH Co KG Mauergasse 5 89143 Blaubeuren Germany Tel 49 7344 171 0 Web www spobu de Mail info spobu de ...