UTM20 Series Ultrasonic Transit-time Flowmeters
10.3 Setup > Meter
Contains all of the configuration parameters for setting the meter Requires service level passcode or
higher if security is enabled An asterisk (*) indicates the parameter default
Meter Submenus
Options/Descriptions
TRANSDUCER
Select the transducer type:
UZ 2 MHZ
Option UZ when ordered with the UTM20 meter
CX 2 MHZ
Options CA to CS and CZ when ordered with the
UTM20 meter
JZ / KZ EASYRAIL 1 MHZ
Options JZ and KZ when ordered with the UTM20
meter
NZ / RZ / WZ 1 MHZ
Options NZ, WZ and RZ when ordered with the UTM20
meter
HZ 1 MHZ
Option HZ when ordered with the UTM20 meter
LZ / YZ 0 5 MHZ
Option LZ when ordered with the UTM20 meter
MOUNTING
For mounting options, see the transducer user manual
Z PATH
*V PATH
W PATH
Cx TYPE
DTTC TYPE is substituted for MOUNTING when TRANSDUCER DTTC is selected as the
transducer type
CA: ½" ANSI
CB: ¾" ANSI
CC: 1" ANSI
CD: 1¼" ANSI
CE: 1½" ANSI
CF: 2" ANSI
CG: ½" COPPER
CH: ¾" COPPER
CJ: 1¼" COPPER
CK: 1½" COPPER
CL: 2" COPPER
CM: ½" SS TUBE
CN: ¾" SS TUBE
CP: 1" SS TUBE
CQ: 1¼" SS TUBE
CR: 1½" SS TUBE
CS: 2 SS IN TUBE
CT: 1" COPPER