POWER LIMIT FAULT:
Indicates the power limit
protection circuitry has caused the high voltage to
turn off. This fault will occur if the output power
exceeds 105% of programmed value. This fault is
indicated by illumination of both the over voltage and
under voltage led status on the front cover and via
RS-232, USB or Ethernet as Power limit. This is
maximum power limit that can be set 0-1200 watts
via the digital interface. This value is stored in HVPS
memory.