![Spellman DXM100 Series Скачать руководство пользователя страница 22](http://html.mh-extra.com/html/spellman/dxm100-series/dxm100-series_instruction-manual_1346461022.webp)
DXM100 MANUAL
16
118147-001 Rev. D
Chapter 6
M
AINTENANCE
his section describes periodic servicing and
performance testing procedures.
THIS POWER SUPPLY GENERATES VOLTAGES
THAT ARE DANGEROUS AND MAY BE FATAL.
OBSERVE EXTREME CAUTION WHEN WORKING
WITH HIGH VOLTAGE.
6.1 Periodic Servicing
Approximately once a year (more often in high dust
environments), disconnect the power to the unit. Use
compressed air to blow dust out of the inside of the unit.
Avoid touching or handling the high voltage assembly.
High Voltage Cable Plug/Receptacle should be greased
and maintained in accordance to the High voltage
cable manufacturer instructions.
6.2 Performance Test
HIGH VOLTAGE IS DANGEROUS.
ONLY QUALIFIED PERSONNEL SHOULD
PERFORM THESE TESTS
.
High voltage test procedures are described in Bulletin
STP-783, Standard Test Procedures for High Voltage
Power Supplies. Copies can be obtained from the
Spellman Customer Service Department. Test equipment,
including an oscilloscope, a high impedance voltmeter,
and a high voltage divider such as the Spellman HVD-100
or HVD-200, is needed for performance tests. All test
components must be rated for operating voltage.
6.3 High Voltage Dividers
High voltage dividers for precise measurements of output
voltage with an accuracy up to 0.1% are available from
Spellman. The HVD-100 is used for voltages up to
100KV. The HVD-200 measures up to 200KV. The
Spellman divider is designed for use with differential
voltmeters or high impedance digital voltmeters. The high
input impedance is ideal for measuring high voltage low
current sources, which would be overloaded by traditional
lower impedance dividers.
T
WARNING
WARNING
Содержание DXM100 Series
Страница 11: ...DXM100 MANUAL 5 118147 001 Rev D Figure 2 1 Unit Dimensions ...
Страница 16: ...DXM100 MANUAL 10 118147 001 Rev D Figure 3 3 Local Programming Via External Voltage Source ...
Страница 17: ...DXM100 MANUAL 11 118147 001 Rev D Figure 3 4 Remote Monitoring ...
Страница 18: ...DXM100 MANUAL 12 118147 001 Rev D RELAY Figure 3 5 Enable Interlock Logic Control ...
Страница 37: ...118142 001 Rev B Page 13 of 104 Figure 9 Web Page 1 Contact Information ...