43
-
(1) Acceleration Time 1 (Bn-01)
Acceleration time 1 is enabled when the accel/decel time change command of multi-function
terminal is "open", or the accel/decel time change function is not provided for the
multifunction terminals. The acceleration time in which frequency reference goes from 0% to
100% is set in the units of 0.1 second.
(2) Deceleration Time 1 (Bn-02)
Deceleration time 1 is enabled when the accel/decel time change command of multi-function
terminals is "open", or the accel/decel time change function is not provided for the
multifunction terminals. The deceleration time in which frequency reference goes from 100%
to 0% is set in the units of 0.1 second.
(3) Acceleration Time 2 (Bn-03)
Acceleration time 2 is enabled when the accelldecel time change command of multi-function
terminals is "closed". The acceleration time in which frequency reference goes from 0% to
100% is set in the units of 0.1 second.
(4) Deceleration Time 2 (Bn-04)
Deceleration time 2 is enabled when the accel/decel time change command of multi-function
terminals is "closed". The deceleration time in which frequency reference goes form 100% to
0% is set in the units of 0.1 second.
(5) Frequency Reference Gain (Bn-05)
The input level when frequency reference voltage is 10V is set in the units of 0.1%.
Examples are shown in the below.
(6) Frequency Reference Bias (Bn-06)
The input level when frequency reference voltage is 0V is set in the units of 0.1%.
<
Example
>
Bn-05 = 50.0
a: Bn-06 = 10.0
b: Bn-06 = -10.0
(7) Torque Compensation Gain (Bn-07)
Torque compensation gain is set in the units of 0.1.
(8) Multi-Function Analog Output A01 Bias(Bn-08)
(9) Multi-Function Analog Output A02 Bias(Bn-09)
The output voltage of Multi-function analog output A01 and A02 can be shifted up
or down by Bn-08 and Bn-09 in the units of % individually.
INPUT LEVEL
Bn-06 is positive value.
%
Bn-05
Bn-06
(a)
10
Bn-06
(b) -10
0 0V
10V
Bn-06 is
negative value.
FREQUENCY
REF.
50%
Содержание 7300PA series
Страница 6: ... 4 PART I INSTALLATION MANUAL ...
Страница 35: ... 33 PART II OPERATION MANUAL ...