Testing the mark position:
Enable the OMR SENSOR.
Load the paper and setup the form as described in fig 2.2 (page24).
Whilst in single feed setup mode, press the infeed button to move the form to the CUT position.
Press the CUT button to prepare the leading edge of the first form.
Then press the START button once to feed and cut one form. If the OMR OFFSET has been entered
correctly the OMR SEEN icon will flash.
If the sensor does not read the OMR registration mark three times in a row the following screen will be