SpectraPure
®
SpectraPure
®
Inc.
480.894.5437 Call us toll-free 1.800.685.2783
2167 East Fifth St, Tempe, Arizona 85281
4
SYSTEM SPECIFICATIONS:
Sediment Prefilter
0.5 micron MicroTec™ sediment prefilter (SF-MT-0.5-10)
Carbon Filter
0.5 micron carbon block prefilter (CF- 0.5-10)
RO Membrane Type
90 GPD SpectraSelect Plus TFC Membrane
(Use 2 for 180 GPD Systems)
DI Cartridges
MaxCap
®
Extended Life Super DI Cartridge (DI-MC-10HC)
SilicaBuster™ Extended Life Super DI Cartridge (DI-SB-10HC
)
Rejection Rate
Typical stabilized conductivity rejection 99%
Minimum conductivity rejection 98%
Input Water Pressure
60 psi (4.15 bar) line pressure*
Input Water Temp
77°F (25°C)
Recovery Rate
33% (i.e. 33% of the water will be collected as pure water)
Dimensions:
MaxCap MC-RODI-180-MF (-AF)
20" W x 16" H x 7" D (Two Membranes)
MaxCap MC-RODI-90-MF (-AF)
20" W x 16" H x 7" D (One Membrane)
Nominal Membrane Flow Rates @ 60 psi, 77° F, & 250 ppm TDS :
GPD Product Water Flow Rate
Concentrate Flow Rate (2:1)
90
234 ml/min
468 ml/min
180
468 ml/min
936 ml/min
Permeate flow and TDS rejection is based on the following test conditions:
250 ppm softened tap water, 77° F (25° C), 33% recovery and 60 psi.
Higher TDS, harder tap water, higher temperature, greater recovery rate, or
lower operating pressure may contribute to reduced permeate flow and/or
lower TDS rejection.
Reverse Osmosis Operating Limits:
Operating Pressure*
40 – 80 psi (2.75 – 5.5 bar)
pH Range
2 – 11
Maximum Temperature
113° F (45° C)
Maximum Turbidity
1.0 NTU
Maximum Silt Density Index
5.0 (based on 15 min. test time)
Free Chlorine Tolerance
less than 0.1 ppm
Maximum Iron
less than 0.1 ppm
Maximum Manganese
less than 0.1 ppm
Maximum Hydrogen Sulfide
0 ppm
*Operating pressure less than 40 psi may require a booster pump:
Operating pressure greater than 80 psi may require a pressure regulator.