16. Upon startup, air may be trapped in the DI cartridges (housing may not
appear full), this is a normal condition and it will not affect the operation of
the DI system. However, when you later install the Float Valve for automatic
operation, all air must be kept purged from the housings by slightly
unscrewing the housing(s) and letting the running water displace the air until
the housings are full of water.
17. Set the right-side meter to “OUT” and run the system until the right-side meter
reads zero. The water is now ready to use.
You can set either meter to read
either probe at any time
.
18. Close the cold water supply valve.
19. Finish the installation by directing or connecting the yellow line to a
permanent drain.
20. Install the included Float Valve onto a collection reservoir. See below.
21. Attach the blue line to the Float Valve.
22. Check the system to ensure that all fittings are tight and leak-free before leaving
the system unattended. (If anything is leaking, contact SpectraPure for assistance.)
23. It may take several days of normal operation for the membrane to reach its full
production rate.
24. (For -AF Systems) Connect the supplied power supply to the 2.1 mm black
female Mini Plug (see Page 10).
INSTALL THE FLOAT VALVE:
1. Drill a 1/2" hole near the top of your reservoir.
NOTE: If you are installing the Float Valve onto an acrylic tank we recommend
using a new Fostner Bit to reduce the chance of cracking the acrylic.
2. (Refer to Diagram on Page 14) Remove the Compression Nut from the float
body.
3. Insert the 1/4" Blue Tubing into the 1/2" Compression Nut with the threads
towards the end of the tube.
4. Unscrew and remove the remaining nut from the float body.
5. Insert the float body and washer into the 1/2" hole and tighten the nut, which
securely tightens the float to the tank wall.
6. Push the Compression Nut towards the end of the tubing and screw the Com-
pression Nut back onto the float body.
7. To tighten, use one 1/2" wrench on the flats of the plastic threads and another
1/2" wrench on the Compression Nut.