RO MEMBRANE REPLACEMENT:
1. Turn off the water supply to the RO system. Place the system where the
membrane housing(s) can be easily accessed.
2. Remove the black tubing from the membrane feed push fitting by
depressing the collar on the fitting with your thumb and pulling the
tubing from the push fitting. You should not have to remove the blue
and yellow tubes.
3. Lift the membrane housing from the retention clips and unscrew the
membrane housing cap. This may require two people.
4. Use a pair of pliers to grasp the membrane stem and pull the membrane
from the housing.
5. Remove the black housing O-ring. Wash the empty housing with soapy
water. Rinse thoroughly with hot, clean water.
6. Insert the new membrane into the housing, with the double O-ring
end first. The o-rings and tube must fit into the recess at the bottom
of the membrane housing. When the membrane is aligned with the
recess, firmly push the membrane into the recess until it bottoms out.
7. Place the black housing O-ring on the housing rim and carefully screw
the lid back on to the base. Hand-tighten.
8. Reconnect the black tubing to the membrane feed push fitting.
9. If you have a dual-membrane system (-180), perform steps 2 thru 8 on
the second membrane.
10. Open the Flush Valve and allow the system to flush for several minutes
to remove any loose particles.
11. Close the Flush Valve and turn on the water supply to the system.
12. Check for leaks.