SpectraLink Corporation
Installation, Configuration, and Administration
NetLink Telephony Gateway
Part Number: 72-0065-02-R.doc
Page 71
Alarm Message
Error
Description
Action
DAA
PBX table unavailable
Bad software load on NetLink
Telephony Gateway
Call SpectraLink Customer
Service.
DAA
PBX type unavailable
Bad software load on NetLink
Telephony Gateway
DAA
DAA type Mismatch
Installed PBX interface cannot be
used to attach to the specified PBX.
Change the specified PBX
or replace the NetLink
Telephony Gateway with a
model that supports the
desired PBX.
DAA
Spoonfeed unavailable
Bad software load on NetLink
Telephony Gateway
Call SpectraLink Customer
Service.
DAA
Bootload unavailable
Bad software load on NetLink
Telephony Gateway
DAA
DSP code unavailable
Bad software load on NetLink
Telephony Gateway
DAA
DSP 1 keepalive
Hardware problem on NetLink
Telephony Gateway
Reset
If problem persists, call
SpectraLink Customer
Service.
DAA
DSP 2 keepalive
Hardware problem on NetLink
Telephony Gateway
DAA
DSP 1 download
Hardware problem on NetLink
Telephony Gateway
DAA
DSP 2 download
Hardware problem on NetLink
Telephony Gateway
DAA
AUX DAA Unknown
Hardware problem on NetLink
Telephony Gateway. Auxiliary DAA
was detected but type is unknown.
Call SpectraLink Customer
Service.
DAA
FPGA Download
Bad software load on NetLink
Telephony Gateway
DAA
FPGA Code Unavailable
Bad software load on NetLink
Telephony Gateway
Line Sync
Line [XX] out of sync (where XX
is 1-16)
The line from the host telephone
system is not communicating with the
NetLink Telephony Gateway.
Check cabling from
telephone system to
NetLink Telephony
Gateway. Check PBX type to
be sure it is correctly
configured.
Reset = reset NetLink Telephony Gateway