37
NOTE: The Ventura contains about 2 gallons of water at any given time, so with 2 gallons in the bucket there will
be a total of 4 gallons of solution.
1.
Close the saltwater intake seacock.
2.
Push the
Freshwater Flush
button to perform a flush.
Repeat
a second flush.
3.
Disconnect the brine discharge hose from the Clark Pump at quick disconnect. Replace with the
vinyl brine service hose*
from your service kit. Lead the service hose into a 5 gallon bucket.
4.
Push
Freshwater Flush
again and stop the feed pump when the bucket has filled with one gallon of
non
-
chlorinated freshwater (or fill a bucket with a gallon of distilled).
5.
Mix one 8 oz. container of SC
-
1 storage compound with the water in the bucket. It will not dissolve
completely, which is normal, and any undissolved particles will be caught by the pre
-
filter.
6.
Connect
black spiraled reinforced service hose**
to the service port (garden hose style fitting)
above the yellow valve on the feed pump module and lead the hose into the
solution in the bucket, creating a closed loop. Turn the yellow service valve to
SERVICE.
7.
Ensure the pressure relief valve on the Clark pump is OPEN (unpressurized), 1/2
turn counterclockwise OR THE MEMBRANE WILL BE DAMAGED.
8.
Turn on the feed pump using
manual
toggle switch***
. The system will draw solution from the
bucket and return it via the brine discharge hose. Circulate the storage solution through the system
for 20 minutes. Turn off the feed pump when finished.
Clean Up:
1.
Remove the brine service hose from the Clark Pump brine discharge using quick disconnect, and
replace with the original hose that leads to the discharge thru
-
hull.
2.
Pump the bucket dry using the
manual toggle switch
, turn off when empty.
3.
Turn the yellow service valve back to RUN. Remove the intake service hose, and replace the cap.
4.
Close the seacock, drain then clean the sea strainer and pre
-
filters. Reassemble dry with new
filters. Leave the pressure relief valve open, since the next time you run the system you will need
to purge the storage chemicals with the system unpressurized.
Your system is now protected from biological growth for 6 months.
Ventura Remote Manual Storage Procedure
**
Intake service hose con-
nected and yellow service
valve handle to SERVICE
*
Connecting brine discharge
service hose at quick disconnect
Service valve OFF, in FLUSH
position
***
Manual toggle switch
**
Black spiraled
reinforced intake
service hose
*
Vinyl Brine Discharge Service
Hose
For further illustration, see Figure 2 on page 38.
Содержание VENTURA 150
Страница 2: ...2...
Страница 4: ...4...
Страница 6: ...6...
Страница 13: ...13 Installation Notes...
Страница 15: ...15...
Страница 16: ...16 John Guest Super Speedfit Fittings...
Страница 26: ...26 Operation...
Страница 27: ...27...
Страница 54: ...54 Insert pdf here after conversion to pdf...
Страница 56: ...56 Exploded Views Part Numbers...
Страница 57: ...57...
Страница 61: ...61 HP TB VEB B HP TB VB HP TB VEB A HP TB BV HP CB CB7 HP CYL SST HP CYL R HP CYL EC HP CYL CCA Not used...
Страница 63: ...63 Parts HP CYL 3 4R...
Страница 64: ...64 PL MTS 3 8X1 2B HP CYL SST HP CYL CCA SO HPP ECCB HP CYL EC HP CYL R HP CYL PT Parts...
Страница 65: ...65...
Страница 69: ...69...
Страница 71: ...71...
Страница 74: ...74...