23
Optional Z
-
Ion Installation
The Z
-
Ion replaces the fresh water flush module on the feed pump module. The Z
-
Ion filter
bowl, like the normal fresh water flush module, houses the charcoal filter, which must be
replaced every six months.
The Z
-
Ion control box comes with four
-
foot cables for flexibility in mounting on the bulkhead
above or adjacent to the feed pump module.
Plug the connector from the Z
-
Ion generator bowl into the connector from the Z
-
Ion control
box.
Connect the power/signal cable, marked green, from the Z
-
Ion control box to the Z
-
Ion control
cable, also marked green, coming from the Spectra Connect box.
Solenoid valve (opens during fresh
water flush/Z
-
Ion treatment)
Z
-
Ion control box
Connector to generator
bowl (2
-
pin)
Connector to Spectra Connect
control box (3
-
pin, labeled green)