background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

Supplied by: 

MACTRAP LTD 

Phone: 

+64 7 549 0414

 

Mobile: 

+64 274 978 791

 

Email: 

[email protected]

 

 

www.mactrap.co.nz

 

Manufactured by MACTRAP Katikati New Zealand

 

 
 
 
 

OPERATIONAL MANUAL

 

MACTRAP GREASE BOSS G15 

EASY CLEAN

 

AUTOMATIC GREASE REMOVAL UNIT (GRU)

 

 

EDITION 2019

 

 

We capture fats, oil & grease

 

Содержание GREASE BOSS G15 EASY CLEAN

Страница 1: ...414 Mobile 64 274 978 791 Email info mactrap co nz www mactrap co nz Manufactured by MACTRAP Katikati New Zealand OPERATIONAL MANUAL MACTRAP GREASE BOSS G15 EASY CLEAN AUTOMATIC GREASE REMOVAL UNIT GRU EDITION 2019 We capture fats oil grease ...

Страница 2: ... The FOG extraction cycle continues intermittently for 24 hours at which time a wash and clean out cycle resets the machine leaving it tidy and clean for the next day s operation On final daily cycle completion when FOG has been removed to external collection water with the FOG removed exits from the unit into the wastewatersystem WHERE CAN GREASE BOSS BE USED Where there is no room for an externa...

Страница 3: ...t solenoid valves to hot water HW line Fit a tap connection to HW line to allow tank service removal and emergency shut off Ensure 1 40 fall at all times for inlet and outlet pipes Do not use a compression hose on inlet side Ensure unit is filled with water prior to switching on power source It is advisable to leave power on to retain integrity of default settings Check correct invert levels herei...

Страница 4: ... FAULT Indicated when PLC window flashes on andoff Note the fault light also occurs when the lid is open POWER ON When the PLC window is illuminated WARNING ALL SYSTEMS 240V TURN OFF MAINS BEFORE SERVICE OR REMOVING COVER Options for outlet connection Connection canbe changed 180 degrees HW connection to solenoid valve ensure a tap is inserted before the solenoid valve for service and emergency st...

Страница 5: ... event of increased loadings to the Grease Boss Do not use harmful detergents to clean the Grease Boss Service contracts by approved engineer are available and recommended UNIT EFFICIENCY CAUTION The passing of dishwasher waste and self cleaning oven waste through the MACTRAP Grease Boss may affect the efficiency of the special roller attraction of fats and oils in the Grease Boss High use of cert...

Страница 6: ...cating studs on the tank sidewall NOTE Keep solids especially coffee grinds onion peel bones utensils and plastics out of the unit This is important to ensure the efficient operation of the extraction process and prevent any build up of rubbish in the chute area To assist and limit problems of internal solids build up before pre wash rising wipe any dairy waste off dishes utensils into rubbish We ...

Страница 7: ...daily Each cycle starts with a hot water wash then a timed FOG extraction period followed by a rinse If water temp rises above 42oC during the day the unit will turn on off regularly in 5 minute intervals ROLLER make sure that you can hear the noise of the roller turning If the motor can be heard but the roller is not turning then check the axles and drive couplings that link the motor to the roll...

Страница 8: ...outlet clear the outlet and drain the line DOES THE INLET GASKET NEED REPLACING General overflowing can also result from a worn inlet gasket or a blocked outlet pipe Replace gasket and clean all possible blockages downstream of the unit Check outlet is not blocked HAS SEDIMENT BEEN ALLOWED TO BUILD UP OVER TIME Over time depending on how the unit has been operated sludge could build up at the bott...

Отзывы: