41
Dealer Access Settings
It is highly recommended that users consult with a factory trained technician before altering any settings
behind the
‘
Dealer Access Point
’.
Changing this settings without understanding the full effect of
each change can void the warranty of your system, and cause irreparable damage.
If any settings are inadvertently changed, they can be reverted back to the defaults by using the
‘
Factory Reset
’
feature.
Purge Setup:
Adjusts the time and maximum feed pressure allowed for the Purge Mode.
CAUTION:
Permanent damage to the membrane can occur if this setting is adjusted. Consult the factory
before making any adjustments.
Fresh Water Flush Settings:
Allows adjustment of the fresh water flush duration and the interval be-
tween flushes. If the Z
-
Ion is installed, the Flush Interval should be changed to 30 days.
Conductivity Setup:
Allows for enabling or disabling conductivity sensors on the feed water and prod-
uct water. Set the threshold for the diversion valve to divert water to the tanks.
Flow Setup:
Allows the user to adjust the flow sensor settings, or disable a flow sensor circuit altogeth-
er.
DO NOT USE THIS SETTING TO CALIBRATE THE PRODUCT FLOW.
Follow instructions on cali-
brating the flow sensor in this manual.
Tank Level Monitors:
Enable and disable the Tank Level Sensors, which read the % remaining in the
tank, and the tank switches, which allow the system to turn on/off automatically.
Boost Pressure Setup:
Enable alternate Boost Pressure sensors, change the Low Vacuum Limit, or
Boost Pressure Setpoint.
CAUTION: Permanent damage to the pump can occur if this setting is
adjusted. Consult the factory before making any adjustments.
Low Vacuum Limit:
The minimum boost pressure required at the inlet to the pump. This setting pre-
vents the pump from getting damaged by running under high vacuum. Adjusting it to a lower number in
creases the risk that the pump will suffer damage during normal operation.
Boost Pressure Setpoint:
During startup the controller turns on the boost pump and waits for the
Boost
Pressure to reach the Boost Pressure Setpoint. If the boost pressure fails to reach this setpoint,
then the
main pump won
’
t turn on. Reducing the Boost Pressure Setpoint may cause the system
to start, then
immediately shut down due to low boost pressure.
Outlet Pressure Setup:
Set High Pressure Limit, enable alternate high pressure sensors, select pres-
sure sensor scaling.
CAUTION: Permanent damage to the pump can occur if this setting is adjust-
ed. Consult the factory before making any adjustments.
Network Setup:
Enabling the Spectra Connect Wireless access turns on a Power Over Ethernet fea-
ture on the wired connection.
ENABLING THIS FEATURE CAN CAUSE SERIOUS DAMAGE TO
YOUR SHIP
’
S NETWORK. DO NOT ENABLE THIS FEATURE WITHOUT CONSULTING A QUALI-
FIED TECHNICIAN OR THE FACTORY.
Dealer Access Point—Settings cont...
Содержание LB-1800C
Страница 2: ...2 Page Intentionally blank...
Страница 4: ...4 Page Intentionally blank...
Страница 33: ...33 Black Parker tube fittings...
Страница 34: ...34 John Guest Super Speedfit Fittings...
Страница 48: ...48...
Страница 49: ...49...
Страница 50: ...50...
Страница 51: ...51...
Страница 52: ...52...