37
Tank Level not accurate
•
Tank Level not calibrated
•
Domestic water pump run-
ning
•
Water tanks sloshing while
underway, no baffles in
tanks
•
Tank sensor failed
•
Calibrate tank level according
to calibration instructions
•
Stop domestic water pump
and check tank level
•
Re
-
check tank level accuracy
while vessel in in port and sea
state is calm
•
Replace sensor
SYMPTOMS
PROBABLE CAUSE
REMEDY
Troubleshooting Spectra Connect
Tank Level shows
‘ ! ‘
•
Tank Level sensor disabled
in Settings
•
Verify tank level sensor is
installed, and enable the tank
level sensor
Device IP in Support Menu
reads
‘
NIL
’
•
Control board not connect-
ed to router or switch
•
Control board not receiving
IP address from router or
switch
•
Connect the control board to a
router or switch according to
the Networking instructions
•
Cycle power on the water-
maker with the network cable
connected
Power suddenly drops out
and watermaker restarts
•
Electrical short, or failed
boost pump
•
Electrical short, or failed
solenoid valve
•
Electrical short, or failed
pressure sensor
•
Electrical short, or failed
speed control
•
Electrical short, or failed
salinity probe
•
Disconnect boost pump wires
from control board and cycle
power. Check boost pump for
electrical short.
•
Replace Boost Pump
•
Disconnect solenoid valves
from control board and check
valve for a short.
•
Replace valve
•
Disconnect speed control and
cycle power. Check speed
control for electrical short.
•
Replace Speed Control
•
Disconnect salinity probe
wires from control board and
cycle power.
•
Replace Salinity Probe
Содержание LB-1800C
Страница 2: ...2 Page Intentionally blank...
Страница 4: ...4 Page Intentionally blank...
Страница 33: ...33 Black Parker tube fittings...
Страница 34: ...34 John Guest Super Speedfit Fittings...
Страница 48: ...48...
Страница 49: ...49...
Страница 50: ...50...
Страница 51: ...51...
Страница 52: ...52...