I
J
H
L
M
H
I
N
O
P
G
F
SO75 GEAR DRIVEN SPRINKLER
SETTING INSTRUCTIONS
NOTE:
The
SO75
is factory preset with a 180° arc setting, and includes a
pre-installed #3 nozzle.
CHANGING A NOZZLE
1. REMOVING THE NOZZLE RETENTION SCREW
Use the hex
(E)
end of the universal tool
(A)
to remove the nozzle retention
screw
(I)
by turning counter-clockwise to remove or clockwise to re-install.
2. PULL UP THE RISER
Insert the pull up key
(D)
end of the universal tool
(A)
in the keyhole on the top
of the nozzle turret
(K)
and turn the key 1/4 turn to insure that the key does not
slip out of the keyhole when you pull it up. Firmly pull up the entire spring-loaded
riser to access the nozzle socket
(J)
. Hold the riser assembly with one hand.
3. REMOVING THE NOZZLE
With nozzle retention screw removed, the nozzle may be removed by either
turning on the water (wear safety glasses when using this method), or by
pulling outward on the nozzle prongs
(G)
with a pair of needle-nose pliers.
4. INSTALLING A NOZZLE
Press the desired nozzle
(F)
into the nozzle socket
(J)
. Make sure the nozzle
number is visible and the nozzle prongs
(G)
are up. Then, re-install the
nozzle retention screw
(I)
.
NOTE:
The nozzle retention screw is also a break-up
screw and used to adjust the distance of the spray.
SETTING THE ARC ADJUSTMENT
NOTE:
The
SO75 Gear Driven Sprinkler
has a fixed right start and an
adjustable left stop.
1. POSITIONING NOZZLE TURRET TO ITS “RIGHT START”
Place your finger on the top center of the nozzle turret
(K)
. Rotate the turret
counter-clockwise to the left stop to complete any interrupted rotation cycle.
Rotate the nozzle turret clockwise to the right start. This is the fixed side of the
arc. The nozzle turret must be held in this position for arc adjustments. The
right start does not change.
2. ADJUSTING THE RIGHT (FIXED) SIDE OF ARC
If the right side of the arc is not properly aligned, the sprinkler may spray in
areas not intended for watering such as driveways or adjacent properties. The
right side arc can easily be realigned.
OPTION 1: REPOSITION CAN ON THE FITTING
Turn the sprinkler can and the fitting below it left or right to the desired
position. This may require temporary removal of the soil around the sprinkler
to allow you to grip the housing can
(M)
.
OPTION 2: REMOVE INTERNAL RISER ASSEMBLY AND REPOSITION
Unscrew the top counter-clockwise and remove the internal sprinkler assembly
(L)
from the can. Once removed with nozzle turret
(K)
at its right start,
reposition the riser assembly so that nozzle arrow points to the desired start
position. Replace the riser assembly back in the can and screw on the top. At
this point you have realigned the right arc stop, and you can adjust the left arc
to an appropriate setting.
3. ADJUSTING THE LEFT (VARIABLE) SIDE OF THE ARC
INCREASING THE ARC
Insert the arc adjustment key
(C)
end of the universal tool
(A)
into the arc set
adjustment slot
(P)
. While holding the nozzle turret
(K)
at the right start, turn
the universal tool clockwise. Each full 360° turn of the universal tool will increase
the arc 90°. Adjust to any arc between 40° and 360°. The universal tool will
stop turning, or there will be ratcheting noise, when the maximum arc of 360°
has been reached.
DECREASING THE ARC
Insert the arc adjustment key
(C)
end of the universal tool
(A)
into the arc set
adjustment slot
(P)
. While holding the nozzle turret
(K)
at the right start, turn
the universal tool counter-clockwise. Each full 360° turn of the universal tool
will decrease the arc 90°. Adjust to any arc between 40° and 360°. The universal
tool will stop turning, or there will be a ratcheting noise, when the minimum
arc of 40° has been reached.
SPRINKLER INSTALLATION
1. INSTALL AND BURY
Do not use pipe dope. Thread the sprinkler on the pipe. Bury the sprinkler
flush to grade.
NOTE:
Gear driven sprinklers and pop-up sprays should not
be installed on the same watering zone.
2. INSPECTING THE FILTER
Unscrew the top and lift the complete sprinkler assembly
(L)
out of the housing
can
(M)
. The filter is located on the bottom of the sprinkler assembly and can
be easily pulled out, cleaned and re-installed.
3. WINTERIZATION TIPS
When using an air compressor to remove water from the system please note
the following:
a.
Do not exceed 30 PSI.
b.
Always introduce air into the system gradually to avoid air pressure surges.
Sudden release of compressed air into the sprinkler can cause damage.
c.
Each zone should run no longer than 1 minute on air. Sprinklers turn 10 to
12 times faster on air than on water. Over spinning rotors on air can cause
damage to the internal components.
C
B
D
E
F
A
Universal Tool
B
Flat Blade
Screwdriver
C
Arc
Adjustment
Key
Pull Up Key
E
Hex Key
H
Key in Keyhole
H
Key in Keyhole
I
Nozzle
Retention
Screw
J
Nozzle
Socket
K
Nozzle
Turret
L
Internal
Sprinkler
Assembly
M
Housing
Can
D
G
Nozzle Prongs
F
Nozzle
STANDARD NOZZLE PERFORMANCE
Pressure Radius Flow
KPa
Bars Meters L/M M
3
/H
206
2.1
11.0
7.6
0.45
275
2.8
11.6
9.1
0.55
344
3.4
12.2
10.2
0.61
413
4.1
12.2
11.0
0.66
206
2.1
8.5
1.9
0.11
275
2.8
8.8
2.3
0.14
344
3.4
8.8
2.7
0.16
413
4.1
9.1
3.0
0.18
206
2.1
8.8
2.6
0.16
275
2.8
9.1
3.0
0.18
344
3.4
9.1
3.4
0.20
413
4.1
9.4
3.8
0.23
206
2.1
9.1
3.4
0.20
275
2.8
9.4
3.8
0.23
344
3.4
9.4
4.5
0.27
413
4.1
9.8
4.9
0.30
206
2.1
9.8
4.5
0.27
275
2.8
10.1
5.3
0.32
344
3.4
10.4
6.1
0.36
413
4.1
10.4
6.8
0.41
206
2.1
11.0
9.8
0.59
275
2.8
12.2
11.4
0.68
344
3.4
12.8
12.9
0.77
413
4.1
12.8
14.0
0.84
206
2.1
11.6
15.9
0.91
275
2.8
13.1
18.5
1.11
344
3.4
14.0
20.8
1.25
413
4.1
14.3
22.7
1.36
275
2.8
13.7
22.7
1.36
344
3.4
14.6
25.7
1.54
413
4.1
14.9
28.8
1.73
482
4.8
15.5
31.0
1.86
Nozzle
#3
#0.5
#0.75
#1
#2
#4
#6
#8
Data represents test results in zero wind for the
SO75 Rotor. Adjust for local conditions. Radius
may be reduced with nozzle retention screw.
LOW ANGLE NOZZLE PERFORMANCE
Pressure Radius Flow
KPa
Bars Meters L/M M
3
/H
207
2.0
6.7
4.5
.34
275
3.0
7.3
6.4
.39
344
3.5
7.9
6.8
.41
413
4.0
8.5
7.6
.46
207
2.0
8.8
11.4
.68
275
3.0
9.8
11.7
.71
344
3.5
10.7
13.2
.80
413
4.0
11.3
14.4
.87
207
2.0
9.4
12.9
.78
275
3.0
10.4
14.8
.89
344
3.5
11.3
16.7
1.00
413
4.0
11.6
17.8
1.07
275
3.0
11.6
24.6
1.68
344
3.5
12.2
27.6
1.66
413
4.0
12.8
30.3
1.82
482
5.0
13.4
32.6
1.96
Nozzle
#1
#3
#4
#6
Nozzle Turret Top
O
Keyhole
P
Arc Set
Adjustment
I
Nozzle
Retention
Screw
RAIN SpA
via Kennedy 38/40
20023 Cerro Maggiore (MI)
Italy
TEL. +39 0331 514511
FAX. +39 0331 421375
www.rain.it
[email protected]
L-16005113
Left
Stop
Right
Start
ENGLISH