SPECTRA PRECISION FOCUS 2 SERIES TOTAL STATION USER GUIDE
5 –
Applications
82
5. To record the distance and angle information as a comment record, press
[REC/ENT]
in the 1/2 or
2/2 observation screen.
Default point numbers are displayed (STN=0, PT=1, PT=2, and so on). These point numbers can
be changed.
6. After recording, the display returns to the
MlmRadial
screen. Sight the third point and press
[MSR1]
or
[MSR2]
. The distances between the first and third point are displayed.
7. Press
[
REC/ENT
]
to record the distances between the first and third point.
8. Repeat the procedure to calculate and record the distance between the first point and other
points.
Mlm Cont.
Measuring between the current point and the immediately preceding point. Other operations are
the same as MlmRadial.
1. From the
Program
, press
[4]
(or press
[v]
and
[REC/ENT]
) to
select
Mlm Cont.
.
The
Mlm Cont.
screen appears.
2. Sight the first point and press
[MSR1]
or
[MSR2]
.
The distance from the station point to the first point is
displayed.