3. Sight the second prism (or target) and press
[MSR1]
or
[MSR2]
.
4. Sight the alternative place on the same vertical line as the required target point.
5. To calculate the coordinates and the raw data of the target point, press
[REC/ENT]
or the
OK
softkey.
6. To record the point, enter a PT (and CD) value and press
[REC/ENT]
. The height of target is fixed to
0.0000 for the offset point.
Note –
The calculated point (TGT) is stored as an SS record.
Note –
Measurements to the first and second target (P1 and P2) are stored as comment records (PT1
and PT2). The last record records the angle measurement to the ALT (vertically offset point from the
actual target point).
Input HD
This function is useful when the instrument is very close to the point and it is difficult to take a
measurement using the EDM.
1. From the
Offset
menu, press
[5]
(or press
[v]
and
[REC/ENT]
) to
select
Input HD
.
The
Input HD
screen appears.
2. Turn the telescope in the direction of the point to be
stored.
3. Enter the HD and press
[REC/ENT]
.
4. Enter a PT (and CD) value and press
[REC/ENT]
.