SPECTRA PRECISION FOCUS 2 SERIES TOTAL STATION USER GUIDE
6 –
Menu Key
118
Station records
Viewing records by station
1. From the
Data
menu, press
[3]
(or press
[v]
and
[REC/ENT]
)
to select
ST
SS/SO/CP
.
The
Stn Data
screen appears.
2. Press
[^]
or
[v]
to scroll through the list.
3. To view detailed information about the selected station,
press
[REC/ENT]
. Press
[ESC]
to return to the list.
4. To display all the observation data from the selected
station, press
[REC/ENT]
again.
Note –
Detailed data is as for raw data. For detailed information about each point type and format,
Deleting station records
1. In the
Stn Data
screen (or in the data screen that appears when you press
[REC/ENT]
), press
[^]
or
[v]
to highlight the record to be deleted. Then press the
DEL
softkey.
2. A confirmation screen appears. Press
[REC/ENT]
or the
OK
softkey to delete the selected record.
(Otherwise, press the
CE
softkey.)
3. A reconfirmation screen appears. Press the
OK
softkey to delete the selected record. (Otherwise,
press the
CE
softkey.)
Editing station records
The system will not recalculate measurements if the station record is changed—this means that the
current station cannot be edited.
1. In the
Stn Data
screen (or in the data screen that appears when
[REC/ENT]
is pressed), press
[^]
or
[v]
to highlight the record to be edited. Then press the
Edit
softkey.
2. Enter the new data manually or select data using the
List
or
Stac
softkey and then press
[REC/ENT]
.
3. To rewrite the data, press
[REC/ENT]
or the
OK
softkey. (Otherwise, press the
CE
softkey.)
The system executes the operation and returns to the
RAW
Data
screen.
Note –
If the station (ST) or instrument height (HI) values are changed, the coordinates of observation