![Spartherm Mellino Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/spartherm/mellino/mellino_installation-and-service-instructions-manual_1340285004.webp)
GB
4
1. INFORMATION
1.1 GENERAL REMARKS
This instruction describes the assembly and the possible service work
required for the pellet stove Mellino. In the first instance, it is intended for
the stove fitter, installation engineer or service technician.
Information for operating and maintaining can be obtained in the „Operating
instructions Mellino“.
Non-observance of the operating instructions may lead to malfunc-
tion and cause severe damage to the device up to its total destruc-
tion. Non-observance of the operating instructions renders the war-
ranty void.
Before assembling the pellet stove, you must have conducted a conversation
with the chimney sweeper responsible for your region. They will advise you
on building regulations, the suitability of your chimney and will carry out the
acceptance test of your pellet stove in the future.
When assembling and commissioning the fire area, please observe the
national and European standards as well as the appropriate country-specific
and local directives and guidelines of the respective firing installation direc-
tive of the federal state and the fire protection guidelines of the VFK.
The assembly and service instruction must be stored in a safe place and
when requested, presented to the chimney sweep or the responsible
authority.
Information on the fuel wood pellets can be obtained in the „Operating
instructions Mellino“.
1.2 TECHNICAL DATA MELLINO
Mains connection
230V AC / 50Hz
Safety class
I
electrical power consumption in standby
approx. 2 W
electrical power consumption when starting
(ignition)
approx. 265 W
electrical power consumption during operation
approx. 20 W
Fuse (10.3 x 38 mm)
2 A slow-blow
Dimensions (WxHxD)
560 mm x 1,241 mm x 510 mm
Total weight, empty
178 kg
Smoke pipe outflow
Ø 100 mm
Combustion air connection
Ø 100 mm
Fuel
Wooden pellets according to DINplus or ÖNorm
standards
Pellet tank capacity
22 kg
Nominal heat output (full load)
8.4 kW
Room heating capacity
71 to 182 m
3
(depending on the building
insulation)
Performance level
1
2
3
4
5 and Hi
2,5 kW
4,0 kW
5,5 kW
7,0 kW
8,4 kW
Efficiency
> 86 %
Average flue gas temperature
140°C
Average necessary supply pressure
12 Pa
CO emissions relating to 13% O2
63 mg/Nm
3
Dust emissions
26 mg/Nm
3
Mass flow of flue gas
9,6 g/s