![Spartherm Mellino Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/spartherm/mellino/mellino_installation-and-service-instructions-manual_1340285026.webp)
GB
26
Error code
Meaning / remedy
E110
Off
Off
On
NTC1 defective (room temperature sensor)
E111
Off
Off
On
K-type sensor 1 defective (flue gas temperature sensor)
E112
Off
Off
On
Overtemperature deactivation
E115
Off
Off
On
General error
10.3 SHIFTING FROM MODULATION / STANDBY
For shifting from operating mode Modulation to operating mode Standby
(see operating instruction, chapter 2.6), proceed as follows
• Scroll through the service menu with the menu keys (the gear wheel
symbol to the right)
• Go to level 7 in the service menu using the + / - setting keys,
[ r - - 0 ] appears
• Press Enter, a random number appears
• Calculate the checksum of this random number and add 1
• Press Enter and set the number calculated using th + / - setting keys
• Press Enter to confirm, ON appears
• Go to level 8 in the service menu using the + / - setting keys,
[ P A r ] appears
• Press Enter, [ P 0 0 0 ] appears. That is the parameter no. 000.
• Use the menu keys to go to parameter P053.
• Press Enter and the current setting value of the parameter appears
flashing
• Use the setting keys + / -, set the value to 0 for Modulation or 20 for
Standby
• To confirm, press Enter
• Press the ESC key at the top left 3 times to return to the home position
10.2 ERROR CODE LIST
Here is a list of the error codes (see chapter 6, level 13). If an error is
reported, determine and eliminate the cause. The errors can be reset by
pressing the On / Off key. The stove can only be restarted after that. If the
error cannot be reset, contact customer services.
Error code
Meaning / remedy
(none)
On
Off
Off
Overtemperature deactivation due to an empty tank.
Top up and fill the feeder spiral.
A001
Flashing
Off
Off
Pellet deficiency (is not activated!)
(none)
Off
On
Off
Burner pot or chimney blocked. Clean. Or the combus-
tion chamber door has been opened during operation.
Close the door.
A002
Off
Flashing
Flashing
Have a service carried out (is not activated!)
A003
Off
Flashing
Off
Burner pot or chimney blocked. Clean.
A004
Off
Off
Flashing
Weak controller battery. Contact customer service.
A005
Off
Off
Flashing
Speed signal from the flue gas fan is faulty (is not
activated!)
A006
Flashing
Flashing
Flashing
Combustion chamber door open (only with door contact
switches, is not activated!)
A007
Off
Off
Flashing
Controller pressure sensor defective
E001
Off
Off
On
Display error or display defective
E002
Off
Off
On
Infrared communication disturbed
E003
Off
Off
On
Remote control data flow defective
E004
Off
Off
On
Controller data flow defective
E101
Off
Off
On
Combustion error, e.g., misfire
E105
Off
Off
On
NTC2 defective (not active!)
E106
Off
Off
On
NTC3 defective (not active!)
E107
Off
Off
On
K type sensor 2 defective (inactive!)
E108
Off
Off
On
STB defective or tripped
E109
Off
Off
On
Pressure switch defective (inactive!)
Содержание Mellino