Form 43343110
May 2021
-7-
BURNER PACKAGE NUMBERS
SINGLE STAGE CONTROLS
TWO STAGE CONTROLS
MODEL NO.
PART NO.
GAS TYPE
MODEL NO.
PART NO.
GAS TYPE
PCA-SS 75-N5
44165250
NATURAL
PCA-SS 75/50-N7
44165750
NATURAL
PCA-SS 100-N5
44165270
NATURAL
PCA-SS 100/65-N7
44165770
NATURAL
PCA-SS 125-N5
44165290
NATURAL
PCA-SS 125/80-N7
44165790
NATURAL
PCA-SS 150-N5
44165310
NATURAL
PCA-SS 150/100-N7
44165810
NATURAL
PCA-SS 75-L5
44165260
PROPANE
PCA-SS 75/50-L7
44165760
PROPANE
PCA-SS 100-L5
44165280
PROPANE
PCA-SS 100/65-L7
44165780
PROPANE
PCA-SS 125-L5
44165300
PROPANE
PCA-SS 125/80-L7
44165800
PROPANE
PCA-SS 150-L5
44165320
PROPANE
PCA-SS 150/100-L7
44165820
PROPANE
COMPLETE MODEL SYSTEM
- Includes Burner Box and Body Package -
MODEL
GAS TYPE
SYSTEM LENGTH
TUBE MATERIAL*
PCA
Series
PCA-SS 75-20-L5
PCA-SS 75-20-N5
Propane
Natural
20 ft.
20 ft.
Aluminized Steel
Aluminized Steel
PCA-SS 75-30-L5
PCA-SS 75-30-N5
Propane
Natural
30 ft.
30 ft.
Aluminized Steel
Aluminized Steel
PCA-SS 100-30-L5
PCA-SS 100-30-N5
Propane
Natural
30 ft.
30 ft.
Aluminized Steel
Aluminized Steel
PCA-SS 100-40-L5
PCA-SS 100-40-N5
Propane
Natural
40 ft.
40 ft.
Aluminized Steel
Aluminized Steel
PCA-SS 125-30-L5
PCA-SS 125-30-N5
Propane
Natural
30 ft.
30 ft.
Aluminized Steel
Aluminized Steel
PCA-SS 125-40-L5
PCA-SS 125-40-N5
Propane
Natural
40 ft.
40 ft.
Aluminized Steel
Aluminized Steel
PCA-SS 125-50-L5
PCA-SS 125-50-N5
Propane
Natural
50 ft.
50 ft.
Aluminized Steel
Aluminized Steel
PCA-SS 150-40-L5
PCA-SS 150-40-N5
Propane
Natural
40 ft.
40 ft.
Aluminized Steel
Aluminized Steel
PCA-SS 150-50-L5
PCA-SS 150-50-N5
Propane
Natural
50 ft.
50 ft.
Aluminized Steel
Aluminized Steel
* The first 10 ft. tube section used for Burner Box mounting is Aluminized Steel on ALL length systems.
STANDARD ACCESSORIES
Part #
Description
30285000
Manual Cut Off Valve
–
CSA listed ball valve ½” (packaged with control unit)
30302360
Gas connector,
5/8” OD x 36” (packaged with control unit)
44129500
Kit, Fresh Air Intake
–
Ceiling
44129510
Kit, Fresh Air Intake
–
Sidewall (includes
4” fresh air intake cap
)
43341000
Kit, Reflector End Panels (packaged with control unit)
42924100
4” Exhaust Hood (for use on heater
UNVENTED)
30297040
4” Vent Cap (for use on heater
VENTED)
When installing a Defender series heater into a barn with stalls or partitions, we
recommend using a model that is no longer than 40 ft. in length. This
recommendation is based on the lower tube temperatures experienced by all
straight tube heaters as the length exceeds 40 ft.
Содержание PCA-SS 100
Страница 13: ...Form 43343110 12 May 2021 7 1 DIMENSIONS STRAIGHT CONFIGURATION 48 HANGING CENTERS...
Страница 14: ...Form 43343110 May 2021 13 7 2 HEATER ASSEMBLY JOINING OF TUBE SECTIONS...
Страница 21: ...Form 43343110 20 May 2021...
Страница 48: ...Form 43343110 May 2021 47 19 0 TROUBLESHOOTING GUIDE SINGLE STAGE N5 L5...
Страница 49: ...Form 43343110 48 May 2021 TROUBLESHOOTING GUIDE SINGLE STAGE CONTINUED...
Страница 50: ...Form 43343110 May 2021 49 TROUBLESHOOTING GUIDE SINGLE STAGE CONTINUED...
Страница 51: ...Form 43343110 50 May 2021 19 1 TROUBLESHOOTING GUIDE TWO STAGE N7 L7...
Страница 52: ...Form 43343110 May 2021 51 TROUBLESHOOTING GUIDE TWO STAGE CONTINUED...
Страница 53: ...Form 43343110 52 May 2021 TROUBLESHOOTING GUIDE TWO STAGE CONTINUED...
Страница 55: ...Form 43343110 54 May 2021 20 2 REMOVING GAS VALVE AND MANIFOLD ASSEMBLY 20 3 AIR SWITCH PRESSURE CHECK...