2.7 Toxicity and Stimulating Substance
A. Do not use the compressor air for breathing.
B. Only operate the compressor outdoors or at a fully ventilated area.
C. When installing the compressor, take into account the air intake position and do not inhale exhaust air
or other toxic or corrosive substances.
D. It is not recommended that this compressor be operated indoors. If the unit is operating indoors, the
diesel engine exhaust shall be transferred to the outdoor area. The unit shall be parked based on the wind
direction to avoid the personnel and compressor from inhaling the diesel exhaust.
E. The fuel, lubricating oil and anti-freeze solution used for the unit shall be protected against skin
contact and swallow. If they are in contact with the skin, wash them off with soapy water. If swallowed
carelessly, treat the patient immediately.
F. Wear an acid-proof apron and a face mask when maintaining the battery. If the electrolyte splashes on
the skin or clothing, rinse immediately with plenty of water.
G. When inspecting the battery or adding anti-freezing agent, wear the appropriate personal protective
equipment according to safety requirements. When the compressor is started, keep the valve open. Do
not direct either discharge ports at operators or other persons.
H. If diethyl ether or anti-freeze agent is splashed into your eyes, rinse immediately with plenty of water
and immediately seek medical attention.
I. Do not store the diethyl ether or anti-freeze agent in or near the workshop.
J. Anti-freeze agent for airline antifreeze system contains methanol which is a toxic substance. Avoid
contact with skin and eyes. Avoid inhaling its volatile air. In case of accidental ingestion, the inhaler
shall lie down, covered with an eye protection article, and immediately ask the doctor for help.
K. The diethyl ether is poisonous. Ingestion can cause death. Avoid skin, eye contact or swallow.
2.8 Electric Shock
A. The unit, tool placing site and operator’s working site, etc. shall be at least 3 m away from the external AC
power sources.
B. The body, hand tools and other electrical conductors shall not contact exposed AC cables. When repairing
and adjusting these parts, stand on insulation objects and do not wet the soles.
C. Select a clean, dry and ventilated site during maintenance.
D. Keep away from the compressor when lightning strike occurs.
2.9 Accidental Winding
A. Close the door on the unit before starting up (to ensure no one is in the unit during start-up). If the
compressor is large enough and it is necessary to carry out maintenance in the unit indeed, other personnel shall