Exterior Lightbar Connect-n-Go System
nROADS Connect-n-Go 1018
16.
NORMAL OPERATION
Under Normal Operation with light bar turned ON, the handheld controller will be backlit.
NO OPERATION
Controller backlight is green;
Check input power and ground to lightbar, check data cable for damage and/or opens.
Check Ignition Input wire and verify a minimum of 10.0 Volts is present on the wire.
Defective power distribution assembly – replace.
NO or INCORRECT INBOARDS or CORNERS LIGHTS (WARNING)
Controller backlight is green; Check DIP switches on driver modules in light bar. Verify they are all set correctly.
NO TAKEDOWNS LIGHTS
Controller backlight is green;
Verify configuration and make sure light modules are configured for takedown function.
NO LIGHT OPERATION IN ONLY 1 TUB
Controller backlight is green;
Remove top cover of tub in which lights are not functioning. Verify DIP switch is set correctly.
Check LED on driver module PCB is flashing when power is applied to any input wire on breakout
box. If there is no LED illumination check for voltage across RED and BLACK power input wires to
driver module. If voltage is present, replace driver module. If voltage is not present, locate the
power distribution PCB (possibly in different tub) and verify fuse is not blown open. If fuse is
blown, check for shorts in cabling replace any damaged cables and replace fuse. If fuse blows
again, replace defective driver module assembly.
INCORRECT OR NO ARROW OPERATION
Controller backlight is green; Verify configuration and make sure light modules are configured for arrow function.
Verify lightbar length is properly set.
MPOWER® MODULES
mpower® modules aren't flashing Verify mpower® modules are plugged into the controller board and verify the configuration
or lighting up for work light;
to make sure that modules are set to flash and/ or work light.
mpower® modules aren't flashing
Verify configuration. Ensure modules are set to flash and/ or work light one, or both colors.
the right color/ work light is wrong color; Also, verify the right colors are selected.
Rear mpower® modules aren’t flashing in Verify configuration and make sure modules are set to flash. Verify mpower® modules have the right
sync with rear of bar/ front mpower® ID's using Program 8.
modules aren’t flashing in sync with
front of bar;
Rear mpower® modules are flashing Verify configuration and make sure modules are set to flash. Verify mpower® modules have the
with front of bar/ front mpower®
right ID's using Program 8.
modules are flashing with rear of bar;
Rear mpower® modules light up for Verify configuration and make sure modules are set to flash. Verify mpower® modules have the
front work light/ front mpower®
right ID's using Program 8.
modules light up for rear work light;
CONNECT-N-GO SYSTEM TROUBLESHOOTING
Note:
Entering factory reset mode will reset lightbar to factory settings.