2-7 (E)
VPL-EX100
2. Install the Linux Gadget Serial Driver. (First time only)
(1) Connect the power cable to this unit, then make it standby state.
(2) Connect this unit with PC using the USB cable. (Refer to USB connection in Section 2-4-1.)
PC recognizes the Gadget Serial and the install of driver starts automatically.
(3) Select “Linux Gadget Serial Driver” (supplied with the application) for destination location.
(4) The install is completed
m
.
Reboot of PC may be required.
.
Depending on PC, the installation/recognition of the Linux Gadget Serial Driver may fail. In
this case, use the USB-RS-232C dual connection.
3. Double-click FlashUpgrader.exe to start the application.
Application name: Pixelworks ImageProcessor SDK FlashUpgrader/SONY Custom
File
name: FlashUpgrader.exe
4. Set the writing settings.
Common
settings:
.
Select Flash in Modes.
.
Place the check on Notify On Completion.
.
Place the check on Reset Target After Download.
For RS-232C connection:
.
Select Serial.
.
Select the serial port number used for connecting PC in COM Port.
.
Select 115200 in Baud Rate.
.
Place the check on UART_SW.
For USB-RS-232C dual connection:
.
Select USB-SONY.
.
Select the serial port number used for connecting PC by RS-232C in COM port.
.
Select 38400 in Baud Rate.
For USB connection:
.
Select USB-SONY.
.
Select the serial port number used for connecting Gadget Serial in COM port.
.
Select 115200 in Baud Rate.
5. Select the update
fi
le.
Click
the
[Choose...]
button, then select the target inf
fi
le.
6. Click
the
[Flash]
button.
The update starts and a status bar is displayed.
Moreover,
the
[Flash]
button changes to the
[Cancel]
button.
When the message “Flash Completed!” is displayed, the update is completed.
Or when the
[Cancel]
button changed to the
[Flash]
, the update is completed.
7. When continuing the update, perform the following.
For RS-232C connection:
Turn off and on the power of this unit, then perform the
procedure from step 5.
For USB-RS-232C dual connection:
Change the Connection setting to “USB-FS”, then
perform the procedure from step 5.
For USB connection:
Change the Connection setting to “USB-FS”, then
perform the procedure from step 5.
8. After the update is completed, disconnect the AC plug.