1-9 (E)
VPL-EX100
5
Two screws
(BVTP3
x
10)
7
Three screws
(BVTP3
x
10)
8
Optical block
4
Lens cap
6
Dial assembly
Rotate the dial assembly to the
end in the clockwise direction,
then install it.
When rotate the dial assembly to the end in the
counterclockwise direction, check that the two gears of
the dial assembly are not engaged.
Lens:
Rotate the focus/zoom gear
to the end in the counterclockwise
direction.
When attaching the dial assembly:
After the dial assembly is attached:
Dial assembly
Lens
1
Loosen the two screws
(with
stoppers).
3
Lamp
assembly
2
Lamp connector assembly
n
When attaching, be sure to insert
the lamp assembly into the lamp
connector assembly.
Bottom side of this unit
1-3-7. Optical Block
.
Remove the upper case assembly. (Refer to Section 1-3-1.)
.
Remove the rear panel. (Refer to Section 1-3-2.)
.
Remove the main board. (Refer to Section 1-3-3.)
.
Remove the G board. (Refer to Section 1-3-4.)
.
Remove the lamp duct. (Refer to steps
1
and
2
in Section 1-3-5.)
.
Remove the speaker. (Refer to Section 1-3-6.)