Installation Requirements
Venting using the optional exhaust duct adaptor
An 8-inch Exhaust Duct Adaptor LKRA-001 is available as an option. This will work with an 8-inch air-conditioning
vent hose.
By replacing the fan cover at the rear of the projector with this adaptor, warm exhaust air from the projector can be
vented to an external location.
To use this adaptor, a heat extractor and a blower capable of exhausting air are also required.
LKRA-001 Front
LKRA-001 Side
Model name
Air flow requirements
SRX-S110/R110
13.7 to 15.6 cube meters/min (450 to 550 cube feet/min)
SRX-S105/R105
13.7 to 15.6 cube meters/min (450 to 550 cube feet/min)
100 (4)
257 (10 1/8)
32.5
°
ø200 (7 7/8)
Unit: mm (inches)