28
SRX-series 4K Projector - System Installation Guide
8
How to control the projector
8-1. Overview
There are three types of controls available for the projectors.
1. RS-232C (including the method using the supplied SRX Controller software)
2. Ethernet (including the method using the supplied SRX Controller software)
3. Supplied IR Remote Commander unit
8-2. RS-232C Pin assignment
8-3. Ethernet
Control through a network that uses Ethernet is possible.
Specification of 10Base-T/100Base-TX or an automatic selection is also available.
Connection to the host PC can be made via an Ethernet hub or an Ethernet cross cable.
All the used ports are shown in the list below.
Pin number
Signal name
Meaning
1
NC
2
RD
Received Data
3
TD
Transmit Data
4
DTR*
Data Terminal Ready
5
GND
Ground
6
DSR*
Data Set Ready
7
RTS**
Request to Send
8
CTS**
Clear to send
9
NC
1
2
3
4
6
7
8
9
5
1
2
3
4
6
7
8
9
(D-sub 9-pin, female)
Function
Port No.
Factory default values
Changes
Used/unused
Port No.
SDAP
53862
Automatic start
Possible
Possible
SDCP
53484
Automatic start
Not possible
Possible
SMTP
25
Unused
Possible
Not possible
POP3
110
Unused
Possible
Not possible
SNMP
161
Unused
Possible
Not possible
NTP
123
Unused
Possible
Not possible
HTTP
80
Automatic start
Not possible
Not possible
* Circuit between pins 4 and 6 is short-circuited in the projector.