5-11 (E)
SRX-R515P
.
In the case of placing a check in “Synchronized with SMS Server”:
The clock inside the server (Secure Clock) is set being synchronized with the clock on the screen
(SMS Server Time).
.
In the case of placing a check in “Force limitless clock setting”:
The current date and time of SMS Server is displayed. To change “Date” and “Time”, it is required
to type the password.
n
When setting the time that is different from the current time by 6 minutes or more, it is required to
place a check in “Force limitless clock setting” and enter the password. If the password is not entered,
an error is displayed when the
[Apply]
is tapped.
7. Set “Time Referenced” as required.
.
In the case of placing a check in the “Synchronized with IMB” radio button:
The clock on the screen (SMS Server Time) is set being synchronized with the clock inside the
server (Secure Clock Time).
.
In the case of placing a check in the “Synchronized with NTP Server” radio button:
The clock on the screen (SMS Server Time) is set being synchronized with the clock of the NTP
server (NTP Secure Time).
“NTP Server” can be entered. The IP address of NTP Server can be entered.
8. Tap
[Apply]
.
9. When “Time Zone” is changed, restart the system manually.