Menu Configuration and Basic Operation
62
Primary
menu
Secondary
menu
Operation/
adjustment item
Settings
Function
Factory default
SETTING
(Continue)
VR REL
MODE SET
1)
WHITE
Select from 1/1,
1/2, or 1/4
Sets variable range for white balance
in Relative mode
1/2
BLACK (FLARE) Select from 1/1,
1/2, or 1/4
Sets variable range for black (flare)
balance in Relative mode
1/2
DETAIL
Select from 1/1,
1/2, or 1/4
Sets variable range for detail level in
Relative mode
1/2
B.GAM
Select from 1/1,
1/2, or 1/4
Sets variable range for black gamma
in Relative mode
1/2
RCP No. SET
RCP No.
1 to 24
Specifies System Number (RCP
Number) of RCP unit
3)
—
PREVIEW
CONTACT
ON/OFF
Sets function for preview signal output
from EXT I/O connector on RCP
ON
CCU
ON/OFF
Sets function for preview signal output
from CCU
OFF
S-BUS
ON/OFF
Sets function for preview signal output
to S-BUS system
OFF
LED
BRIGHTNESS
SWITCH/LED
0 to 99
Sets lighted switch and LED
brightness
50
TALLY
0 to 99
Sets tally indication window
brightness
50
7SEGMENT
0 to 99
Sets brightness for 7-segment LED
display (MASTER GAIN/ND/CC
FILTER/IRIS/MASTER BLACK)
50
BUZZER
VOLUME
SWITCH
0 to 99
Sets volume of the sound emitted
when a switch on the RCP is pressed
50
CALL
0 to 99
Sets call volume of buzzer
50
TIME
DATE
XXXX / XX / XX
Sets date
—
TIME
XX : XX
Sets time
—
TIME ZONE
COUNTRY
Sets time zone
(GMT) London
SECURITY
MODE
MODE
NORMAL/
ENGINEER
Specifies security level
NORMAL
SET
—
Specifies mode
—
CNS
SETTING
1)
CNS MODE
LEGACY/
BRIDGE/MCS
Sets camera network system
connection mode
LEGACY: System connection using
conventional 700 protocol cable
BRIDGE: Mode for one-to-one
connections using the network
MCS: Mode for multi-camera systems
using the network
LEGACY
(Sub mode)
LEGACY: None
BRIDGE:
CONNECT
MCS: M/C
CONNECT:
PASSIVE/
ACTIVE/SEMI-AT
Sets submode for bridge mode
PASSIVE: Waits for connection
ACTIVE: Actively connects
SEMI-AT: Semi-automatic mode that
switches between PASSIVE/ACTIVE
based on device connected via 700
protocol
SEMI-AT
M/C:
CLIENT
Sets submode for multi-camera
system mode
CLIENT
MASTER IP
ADDR
xxx.xxx.xxx.xxx
Sets master IP address of multi-
camera system mode
0.0.0.0
TARGET IP
ADDR
xxx.xxx.xxx.xxx
Sets IP address for connection target
in bridge mode
0.0.0.0
Содержание RCP-750
Страница 43: ......
Страница 75: ...Printed in Japan Sony Corporation ...
Страница 88: ...12 E Mounting on a Console The RCP 750 751 can be mounted on a console as shown below ...
Страница 108: ...RCP 750 751 SY 3 206 914 05 1 Printed in Belgium 2008 06 08 2002 Sony Corporation 3 2 0 6 9 1 4 0 5 1 ...
Страница 146: ...Specifications 77 ...
Страница 147: ...Specifications 78 ...
Страница 149: ...Sony Corporation RCP 920 SY RCP 921 SY 3 096 914 03 1 Printed in Belgium 2008 06 08 2006 3 0 9 6 9 1 4 0 3 ...