HXCU-100
4-140-418-
12
(1)
15
\\Dell2\temporary\osw\YIT\SAKURA~1.04\HXCU-100\nouhin\GB-P\4140418121_HXCU100UC\02GB04MENU.f
m
masterpage:Right
Status Display
Status Display
The CCU system status can be monitored using a picture
monitor connected to the PIX output.
For information on monitoring and changing settings, see
“Setup Menu” on page 18.
Displaying the Status Screen
The status screen is controlled using the knob and levers in
the MENU control block on the front panel.
To display the status screen
Set the DISP/MENU lever to the DISP position.
The most recently viewed status screen page is displayed
(when first powered on, the camera settings page is
displayed).
Turning the CONTROL knob changes the displayed page.
To exit the status screen display
In status screen display mode, set the DISP/MENU lever to the
DISP position.
Status Display Screen
The following information is displayed on the status display
screen.
• Camera settings
• System status
• CCU hardware diagnostics
• Camera system diagnostics
• Network diagnostics
• CCU SY board diagnostics
• CCU DPR board diagnostics
• Front panel diagnostics (displayed only when the
HKCU-FP1 CCU Control Panel is fitted)
• Camera hardware diagnostics
• ROM version information for major components
Camera settings
Page 1
a
Master gain value
Video output signal gain (dB units)
b
Shutter speed/Clear scan frequency
Shutter speed value. When ECS is on, the clear scan
frequency is displayed.
c
Shutter/ECS
Shutter/ECS on/off indicator
d
Camera auto control information area
Top
: Displays the Auto Setup category and execution status
Bottom
: Displays the execution item
e
ND filter
Current ND filter selection
f
F-stop value
Lens f-stop value (iris value)
g
EX (lens extender)
Lens extender indicator
• Items that are turned off using the <DISPLAY> page settings of the
CCU CONFIGURATION menu are not displayed.
• A “-” mark is displayed for each item when a camera is not
connected.
• Even if an HSC-300 is connected, the CC filter selection is not
displayed.
Page 2
White
: White balance R/G/B value
Black
: Black balance R/G/B/Master value
BLK
γ
: Black gamma value
Flare
: Flare balance R/G/B value
DTL
: Detail level
The items along the bottom edge are common to both pages 1 and 2.
DISP/MENU lever and indicator
CONTROL knob
Notes
Note
6dB 1/2000 OFF
ND:1 F:4.7 EX
a
e
f
g
b
c
d
6dB 1/2000 OFF
White Black
R: 0 R: 0
G: 0 G: 0
B: 0 B: 0
M: 0
BLK
γ
Flare
: 0 R: 0
DTL G: 0
: 0 B: 0
ND:1 F:4.7 EX
Содержание RCP-750
Страница 43: ......
Страница 75: ...Printed in Japan Sony Corporation ...
Страница 88: ...12 E Mounting on a Console The RCP 750 751 can be mounted on a console as shown below ...
Страница 108: ...RCP 750 751 SY 3 206 914 05 1 Printed in Belgium 2008 06 08 2002 Sony Corporation 3 2 0 6 9 1 4 0 5 1 ...
Страница 146: ...Specifications 77 ...
Страница 147: ...Specifications 78 ...
Страница 149: ...Sony Corporation RCP 920 SY RCP 921 SY 3 096 914 03 1 Printed in Belgium 2008 06 08 2006 3 0 9 6 9 1 4 0 3 ...